Figure 3: Cleaning unit
Connection between pipes must be always made with male fitting turned upwards (
figure 4
).
It is advisable to avoid using horizontal connections of pipes to flue. If this is not possible, the
pipes must not be installed in a downwards angle, but at an upwards angle of at least 5 %
(
figure 5
). Horizontal installation of pipes must not exceed 2 m in length.
It is not advisable to connect the pipe from the pellet boiler directly to flue with horizontal
pipe, longer than 1 m.
Figure 4 Figure 5
Direction of smoke
gases
NO
YES
5% or
more