Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

HIGH VOLTAGE!

 DISCONNECT ALL POWER BEFORE SERVICING.

MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO

MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

WARNING

Wiring Diagram

CIRCULATOR BLOWER

1

1

CIRCULATOR

CIRCULATOR

RD

WH

TO

MICRO

AUX IN

AIR

230 VAC

PL1

SEE

NOTE 7

DEHUM

24 VAC

RD

4

BLWR

5

AIR

40 VA

8

40 VA TRANSFORMER, SEE NOTE 1

L1

9

INDOOR

7

24 VAC

4

BK

1

5

BL

PL2

FUSE 3 A

208/230 VAC

GRND

ECM MOTOR

HARNESS

GRND

6

L2

6

L1

COM

BR

G

INTEGRATED CONTROL MODULE

W

BK

3

24V
 T

HE
RM
O

S

TA

T CO
NNE

CT
IO

NS

COM

L2

DISCONNECT

BL

BK

TR2

C

3

GRND (4)

2

2

INDOOR

9

RD

TH2

+VDC (1)

Y

208 VAC

BK

RX (2)

RD

GRND

GRND

4

GN

R

8

5

EH1

RD

TX (3)

BL

3

GRND

ELECTRIC STAGE 2

RD

TRANSFORMER

ELECTRIC HEAT STAGE 1

GN

7

2

BLWR

EQUIPMENT GRND

TERMINAL

PLUG CONNECTION

LOW VOLTAGE FIELD

HI VOLTAGE FIELD

JUNCTION

HI VOLTAGE (230V)

PROT. DEVICE

INTEGRATED CONTROL

LOW VOLTAGE (24V)

FIELD SPLICE

      INTERNAL TO

FIELD GRND

 OVERCURRENT

BK ---- BLACK

OR ---- ORANGE

BL ----  BLUE

PK ---- PINK

GY ---- GRAY

RD ---- RED

WH ----WHITE

PU ---- PURPLE

YL ---- YELLOW

BR ---- BROWN

COLOR CODES:

GN ---- GREEN

NOTES:

1. PLACE RED WIRES ON TRANSFORMER TERMINAL 2 FOR 208 VAC OPERATION.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

    HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY.

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES.

5. TO RECALL THE LAST 6 FAULTS, DEPRESS THE RIGHT PUSH BUTTON FROM STATUS MENU ONCE AND THEN

    USE THE LEFT OR RIGHT BUTTON TO REVIEW ALL THE FAULTS HISTORY.

6. 2 GREEN LEDS INDICATES CLIMATE TALK AND DATAAC NETWORK TRAFFIC STATUS. USE LEARN MENU FOR CLIMATE TALK NETWORK RESET.

7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.

8. THE CONDENSATE ALARM SWITCH (AUX) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING MODE SETUPS AND MUST BE ENABLED WITH

    COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT OPERATIONAL WITH NON COMMUNICATING SYSTEMS.

9. USE N.E.C CLASS 2 WIRE.

10. SEE MANUAL FOR PUSH BUTTON OPERATION

11.

SEE MANUAL FOR 7-SEGMENT DISPLAY DIAGNOSTIC CODES AND MENU CODES

12. SEE MANUAL FOR LEDS FUNCTIONALITY

13. R AND C TERMINALS (USED FOR 24VAC OUTDOOR CONTROL VOLTAGE) ARE OPTIONAL FOR 2 STAGE COMMUNICATING AIR CONDITIONERS. R AND C TERMINALS

       ARE NOT TO BE USED FOR 2 STAGE COMMUNICATING HEAT PUMP APPLICATIONS.

       FOR COMMUNICATING HEAT PUMP OR IF ONLY TWO THERMOSTAT WIRES ARE AVAILABLE, A SEPARATE TRANSFORMER MUST BE INSTALLED IN THE OUTDOOR

       UNIT FOR CONTROL BOARD POWER.

       1 AND 2 WIRES ARE REQUIRED FOR ALL APPLICATIONS. SEE INSTALLATION MANUAL FOR FULL SYSTEM WIRING EXAMPLES.

0140A00705-A

1

2

3

CONDENSATE SWITCH

AUX OUT

EH2

RESISTOR

4

3

2

1

SEE N

O

TE 9

4 - GND

NC

SEE NOTE 6

G

Y

P

U

WH
G

R

B

L

R

D

B

L

R

D

G

Y

BK

TH

ER
MO
ST

AT

O

UT
DO
O

R UNI

T

 (SEE N

O

TE 1
3)

Summary of Contents for MBVC 1 Series

Page 1: ...MENT THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES IF YOU SERVICE THIS UNIT YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR...

Page 2: ...edobjects etc If you come in contact with an ungrounded object repeat step 2 before touching control or wires 4 Discharge your body to ground before removing a new control from its container Follow st...

Page 3: ...ons Internal algorithms will provide 2 stage or inverter Air Conditioner or Heat Pump functionality based on these simple inputs With built in Bluetooth operation the CoolCloud HVAC phone appli cation...

Page 4: ...f the blower cabinet Figure 3 NOTE All panels should be in place when installing the unit NOTE Supply ductwork for counterflow applications must be Class I However if combustible ductwork is used shee...

Page 5: ...disconnected during shipping and handling 208 230 Volt Line Connections If heater kits will not be installed remove the proper size knockout for the electrical conduit connection Connect electrical c...

Page 6: ...et on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Actual screens may look different based on the mobile device be...

Page 7: ...show Release the RECAL button 7 Press and hold the RECALL button again for another 5 seconds the 7 Segment display should show Release the RECALL button 8 Press and hold BOTH the RECALL AND TEST butt...

Page 8: ...he system has already terminated charge mode Pressing the LEARN button will exit the menus If after pressing the RECALL button at step 8 the 7 Segment displays still show press RECALL to change the di...

Page 9: ...e stage Heat Pumps for two stage Air Conditioners and for 2 stage Heat Pumps 4 Go to the Tonnage Units Menu and select the tonnage valuethatcorrespondstothedesiredairflowfortheoutdoor unit See the fol...

Page 10: ...or the thermostat energizes this terminal when dehumidifcation is required set the control board Dehum Logic Menu to using the push buttons or CoolCloud HVAC phone application If the humidistat opens...

Page 11: ...ermostatto ensureGsignal isenergized during accessory operation Figure 15 4 Select the appropriate fan only airflow for the accessory using the indoor unit push button menus or the CoolCloud HVAC phon...

Page 12: ...in a person s hand during grounding will be discharged 3 Service integrated control module or connecting wiring following the discharge process in step 2 Use caution not to recharge your body with sta...

Page 13: ...disconnected wiring connection at circulator motor power leads Open circuit in inductor or loose wiring connection at inductor 3 4 Hp and 1 Hp models only Failed circulator blower motor Tighten or co...

Page 14: ...necessary No Air Handler operation Circulator blower motor shuts down for over or under voltage condition Circulator blower motor shuts down due to over temperature condition on power module High or...

Page 15: ...Airflow Trim default 0 Cooling Airflow Profile setting default profile D shown as 4 Cooling Airflow On Delay Time default 5 seconds Cooling Airflow Off Delay Time default 60 seconds Percentage of hig...

Page 16: ...the next heat call if the heat pump fails to satisfy the custom target time for this number of consecutive cycles default 20 cycles Menu is enabled if the menu is set to 6 if the addition of low stag...

Page 17: ...nits Compressor Heat Low Stage Comm Units Compressor Heat High Stage Comm Units Electric Heat Single Stage Electric Heat Low Stage Electric Heat High Stage Defrost Single Stage Electric Heat non comm...

Page 18: ...r kit size See Menu Navigation and Selection Instructions above Default selection is 0 No Heat Kit Select installed heater kit for heater kit operation NR Not Rated Electric Heat Airflow Table Menu Na...

Page 19: ...ACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C USE COPPER CONDUCTORS ONLY 4 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES 5 TO REC...

Page 20: ...and drain pan tab lets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum...

Page 21: ...21 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 22: ...22 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 23: ...23 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 24: ...p www amana hac com about us contact us You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page GOODMAN BRAND AMANA BRAND GOODMAN BRAND AMANA...

Reviews: