9
Non-Communicating Two Stage A/C
Figure 11
Non-Communicating SIngle Stage Heat Pump
Figure 12
Non-Communicating Two Stage Heat Pump
Figure 13
2. Download the
CoolCloud
HVAC phone application.
Note:
When new versions of Bluetooth Communication Software
and Air Handler Control Software are available, the phone appli
-
cation notifies the user. Software updates are classified as either
optional or mandatory and installed by using the phone application.
Ensure all mandatory software updates have been installed. Review
notes for optional software updates and install if necessary.
3. Go to the Non-Comm Outdoor Setting Menu (
) using
the on board push buttons or the
CoolCloud
HVAC phone
application. Select “
” for single stage Air Conditioners,
“
” for single stage Heat Pumps, “
” for two stage Air
Conditioners and “
” for 2 stage Heat Pumps.
4. Go to the Tonnage Units Menu (
) and select the tonnage
value that corresponds to the desired airflow for the outdoor
unit. See the following table.
NOTE:
For the two stage non-communicating outdoor units, system
will stage airflow automatically for low stage operation.
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
1
400
2.3
920
3.6
1440
4.9
1960
1.1
440
2.4
960
3.7
1480
5
2000
1.2
480
2.5
1000
3.8
1520
5.1
2040
1.3
520
2.6
1040
3.9
1560
5.2
2080
1.4
560
2.7
1080
4
1600
5.3
2120
1.5
600
2.8
1120
4.1
1640
5.4
2160
1.6
640
2.9
1160
4.2
1680
5.5
2200
1.7
680
3
1200
4.3
1720
5.6
2240
1.8
720
3.1
1240
4.4
1760
5.7
2280
1.9
760
3.2
1280
4.5
1800
5.8
2320
2
800
3.3
1320
4.6
1840
5.9
2360
2.1
840
3.4
1360
4.7
1880
6
2400
2.2
880
3.5
1440
4.8
1920
NOTE:
The system will not provide airflows above the max Airflow
Value.