background image

MBVC***1

BLOWER CABINET 

INSTALLATION INSTRUCTIONS

Contents

 is a registered trademark of Maytag 

Corporation or its related companies and is used under license.  All rights reserved.

Introduction

............................................................................ 2

Electrostatic Discharge (ESD) Precautions  ............................

2

Checking Product Received ......................................................

2

Replacement Parts ...................................................................

2

Ordering Parts ........................................................................

2

Important Safety Instructions   ..............................................

2

Recognize Safety Symbols, Words, and Labels .......................

2

General Information ...............................................................

3

Features

.................................................................................... 3

Achieving Less Air Leakage: ......................................................

3

Clearances And Accessibility ...................................................

3

Insulation ................................................................................

3

Installation Instructions ........................................................

4

Blower with Cased Evaporator Coil Installation ...................

4

Upflow Installation  ................................................................

4

Counterflow Installation .......................................................

4

Horizontal Installation ..........................................................

4

Counterflow and Horizontal Applications ............................

5

Electrical Connections ............................................................

5

208/230 Volt Line Connections ................................................

5

Low Voltage Wiring .................................................................

5

Operation on 208 Volt Supply ..................................................

6

24 Volt Thermostat Wiring .....................................................

6

CoolCloud HVAC Phone Application ........................................ 6 

Quick Start Guide for Communicating Outdoor Units .......... 6 

Charging .................................................................................. 7  

Electric Heat Kit Testing .......................................................... 8   

Quick Start Guide for Non-Communicating Outdoor Units .. 8  

Charging ..................................................................................

9

Electric Heat Kit Testing ..........................................................

9

Dehumidification ..................................................................... 9 

Auxiliary Alarm Switch  ........................................................

10

7-Segment Display and Push Buttons ....................................

10

Accessory Control .................................................................

10

Ramping Profiles ...................................................................

11

Electric Air Cleaner ...............................................................

12

Troubleshooting ...................................................................

12

Troubleshooting Matrix .......................................................

13

Push Button Menus ...............................................................

15

System Status Display .............................................................

17

Airflow Label ......................................................................

18

Wiring Diagram ...................................................................

19

Homeowners Routine Maintenance Recommendations ....

20

THIS PRODUCT CONTAINS ELECTRONIC COMPONENTS WHICH REQUIRE A DEFINITE 

GROUND. PROVISIONS ARE MADE FOR CONNECTION OF THE GROUND. A DEDICATED 

GROUND FROM THE MAIN POWER SUPPLY OR AN EARTH GROUND MUST BE 

PROVIDED.

© 2019 - 2020 Goodman Manufacturing Company, L.P.
19001 Kermier Rd., Waller, TX 77484
www.goodmanmfg.com - www.amana-hac.com

P/N:  IO-456A  Date:  February 2020

O

NLY

 

PERSONNEL

 

THAT

 

HAVE

 

BEEN

 

TRAINED

 

TO

 

INSTALL

ADJUST

SERVICE

 

OR

 

REPAIR

 (

HEREINAFTER

, “

SERVICE

”) 

THE

 

EQUIPMENT

 

SPECIFIED

 

IN

 

THIS

 

MANUAL

 

SHOULD

 

SERVICE

 

THE

 

EQUIPMENT

. T

HE

 

MANUFACTURER

 

WILL

 

NOT

 

BE

 

RESPONSIBLE

 

FOR

 

ANY

 

INJURY

 

OR

 

PROPERTY

 

DAMAGE

 

ARISING

 

FROM

 

IMPROPER

 

SERVICE

 

OR

 

SERVICE

 

PROCEDURES

.  I

F

 

YOU

 

SERVICE

 

THIS

 

UNIT

YOU

 

ASSUME

 

RESPONSIBILITY

 

FOR

 

ANY

 

INJURY

 

OR

 

PROPERTY

 

DAMAGE

 

WHICH

 

MAY

 

RESULT

.  I

N

 

ADDITION

IN

 

JURISDICTIONS

 

THAT

 

REQUIRE

 

ONE

 

OR

 

MORE

 

LICENSES

 

TO

 

SERVICE

 

THE

 

EQUIPMENT

 

SPECIFIED

 

IN

 

THIS

 

MANUAL

ONLY

 

LICENSED

 

PERSONNEL

 

SHOULD

 

SERVICE

 

THE

 

EQUIPMENT

.  I

MPROPER

 

INSTALLATION

ADJUSTMENT

SERVICING

 

OR

 

REPAIR

 

OF

 

THE

 

EQUIPMENT

 

SPECIFIED

 

IN

 

THIS

 

MANUAL

OR

 

ATTEMPTING

 

TO

 

INSTALL

ADJUST

SERVICE

 

OR

 

REPAIR

 

THE

 

EQUIPMENT

 

SPECIFIED

 

IN

 

THIS

 

MANUAL

 

WITHOUT

 

PROPER

 

TRAINING

 

MAY

 

RESULT

 

IN

 

PRODUCT

 

DAMAGE

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

.

WARNING

PROP 65 WARNING 

FOR CALIFORNIA CONSUMERS

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

0140M00517-A

This device, which was assembled by Goodman Manufacturing 

Company, L.P., contains a component that is classified as an 

intentional radiator. This intentional radiator has been certified by 

the FCC: FCC ID QOQBGM111. And this international radiator has 

an Industry Canada ID: IC 5123A-BGM111.
This device complies with Part 15 of the FCC’s Rules. Operation of 

this device is subject to two conditions:
(1) This device may not cause harmful interference; and
(2) This device must accept any interference received, including 

interference that may cause undesirable operation.
And this device meets the applicable Industry Canada technical 

specifications.

The manufacturer of the intentional radiator (model no. BGM111) is 

Silicon Laboratories Finland Oy, which can be contacted by calling 

617-951-0200. (www.silabs.com)
The FCC responsible party is Goodman Manufacturing Company, 

L.P., and may be contacted by calling (713)-816-2500, or at 19001 

Kermier RD., Waller TX 77484.  (www.GoodmanMFG.com)
This equipment complies with FCC radiation exposure limits. To 

ensure compliance, human proximity to the antenna shall not be 

less the 20cm during normal operations.

Changes or modifications not expressly approved by the party 

responsible for compliance could void the user’s authority to 

operate the equipment.

Summary of Contents for MBVC 1 Series

Page 1: ...MENT THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES IF YOU SERVICE THIS UNIT YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR...

Page 2: ...edobjects etc If you come in contact with an ungrounded object repeat step 2 before touching control or wires 4 Discharge your body to ground before removing a new control from its container Follow st...

Page 3: ...ons Internal algorithms will provide 2 stage or inverter Air Conditioner or Heat Pump functionality based on these simple inputs With built in Bluetooth operation the CoolCloud HVAC phone appli cation...

Page 4: ...f the blower cabinet Figure 3 NOTE All panels should be in place when installing the unit NOTE Supply ductwork for counterflow applications must be Class I However if combustible ductwork is used shee...

Page 5: ...disconnected during shipping and handling 208 230 Volt Line Connections If heater kits will not be installed remove the proper size knockout for the electrical conduit connection Connect electrical c...

Page 6: ...et on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Actual screens may look different based on the mobile device be...

Page 7: ...show Release the RECAL button 7 Press and hold the RECALL button again for another 5 seconds the 7 Segment display should show Release the RECALL button 8 Press and hold BOTH the RECALL AND TEST butt...

Page 8: ...he system has already terminated charge mode Pressing the LEARN button will exit the menus If after pressing the RECALL button at step 8 the 7 Segment displays still show press RECALL to change the di...

Page 9: ...e stage Heat Pumps for two stage Air Conditioners and for 2 stage Heat Pumps 4 Go to the Tonnage Units Menu and select the tonnage valuethatcorrespondstothedesiredairflowfortheoutdoor unit See the fol...

Page 10: ...or the thermostat energizes this terminal when dehumidifcation is required set the control board Dehum Logic Menu to using the push buttons or CoolCloud HVAC phone application If the humidistat opens...

Page 11: ...ermostatto ensureGsignal isenergized during accessory operation Figure 15 4 Select the appropriate fan only airflow for the accessory using the indoor unit push button menus or the CoolCloud HVAC phon...

Page 12: ...in a person s hand during grounding will be discharged 3 Service integrated control module or connecting wiring following the discharge process in step 2 Use caution not to recharge your body with sta...

Page 13: ...disconnected wiring connection at circulator motor power leads Open circuit in inductor or loose wiring connection at inductor 3 4 Hp and 1 Hp models only Failed circulator blower motor Tighten or co...

Page 14: ...necessary No Air Handler operation Circulator blower motor shuts down for over or under voltage condition Circulator blower motor shuts down due to over temperature condition on power module High or...

Page 15: ...Airflow Trim default 0 Cooling Airflow Profile setting default profile D shown as 4 Cooling Airflow On Delay Time default 5 seconds Cooling Airflow Off Delay Time default 60 seconds Percentage of hig...

Page 16: ...the next heat call if the heat pump fails to satisfy the custom target time for this number of consecutive cycles default 20 cycles Menu is enabled if the menu is set to 6 if the addition of low stag...

Page 17: ...nits Compressor Heat Low Stage Comm Units Compressor Heat High Stage Comm Units Electric Heat Single Stage Electric Heat Low Stage Electric Heat High Stage Defrost Single Stage Electric Heat non comm...

Page 18: ...r kit size See Menu Navigation and Selection Instructions above Default selection is 0 No Heat Kit Select installed heater kit for heater kit operation NR Not Rated Electric Heat Airflow Table Menu Na...

Page 19: ...ACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C USE COPPER CONDUCTORS ONLY 4 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES 5 TO REC...

Page 20: ...and drain pan tab lets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum...

Page 21: ...21 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 22: ...22 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 23: ...23 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 24: ...p www amana hac com about us contact us You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page GOODMAN BRAND AMANA BRAND GOODMAN BRAND AMANA...

Reviews: