Page 1: ...REMOVAL PROCEDURE S E R V I C E M A N U A L 2 5 3 5 kW Class Outdoor Unit Non Inverter Pair Type Si011404EC...
Page 2: ...35QRV161 RQ35QRV1625 RC35QRV161 RF35QRV1625 RC35QRV1615 RQ35RRV162 RF35RRV161 RQ35RRV1625 RC25RRV162 RF35RRV1615 RC35RRV161 RQA35QRV16 RC35RRV1615 RFA35QRV16 RQA35RRV162 RCA25QRV16 RFA35RRV161 RCA35QR...
Page 3: ...cedure 1 Table of Contents 1 Outer Panels Fan Motor Electrical Components 2 2 Sound Blanket Partition Plate 8 3 Capillary Tube 9 4 Compressor ASSY 10 Note The illustrations may be slightly different d...
Page 4: ...ore after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the outer panels 1 Remove the screw and then the stop valve cover The stop valve cover is united with...
Page 5: ...ews and then the discharge grille The discharge grille has 4 hooks 4 Remove the 7 screws of the front panel 5 Unfasten the 4 hooks and remove the front panel The front panel has 4 hooks Step Procedure...
Page 6: ...nut and then the outdoor fan 2 Cut the clamp and release the fan motor lead wire 3 Pull out the 2 terminals red white from the capacitor C1 Capacitor C1 4 Pull out the terminal 3 front black from the...
Page 7: ...outdoor fan When reassembling fit the 2 lower hooks into the bottom frame 6 Remove the screw and then the fan motor fixing frame 7 8 Release the fan motor lead wire from the 2 hooks Remove the 4 screw...
Page 8: ...the terminal board and disconnect the connecting wire and the power supply wire 5 Remove the 2 screws and then the electrical component mounting plate Step Procedure Points Capacitor R20117 from compr...
Page 9: ...t side panel 1 Remove the 5 screws and remove the right side panel There are 2 hooks on the right side panel When reassembling make sure to fit the 2 hooks Step Procedure Points R20131 Terminal board...
Page 10: ...es or more after turning off all power supplies before disassembling work Step Procedure Points 1 Remove the sound blanket Some models have sound blanket top Since the piping ports are torn easily rem...
Page 11: ...ply nitrogen replacement when heating up the brazed part Do not use a metal saw for cutting pipes by all means because the sawdust comes into the circuit When withdrawing the pipes be careful not to p...
Page 12: ...by non oxidation brazing Note Before working make sure that the refrigerant gas is empty in the circuit Be sure to apply nitrogen replacement when heating up the brazed part Do not use a metal saw fo...
Page 13: ...ect the compressor lead wires Remove the gasket Step Procedure Points Gasket R20126 Pattern 1 Pattern 2 C U white S V red R W blue C U white S V red R W blue Pattern 3 Pattern 4 C U white S W red R V...
Page 14: ...he brazed part of the discharge side pipe and disconnect Heat up the brazed part of the suction side pipe and disconnect Remove the 3 nuts of the compressor Lift the compressor ASSY up and remove it S...
Page 15: ...6 RC35QRV161 RCA25 35QRV16 RCD25 35QRV16 RF35QRV16 RF35QRV161 RFA35QRV16 RFD35QRV16 RQ35QRV16 RQA35QRV16 RQD35QRV16 06 2016 Si011404EC Model addition RC35QRV1615 RC25RRV162 RC35RRV161 RC35RRV1615 RCA2...
Page 16: ...ories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and acc...