background image

4

www.goodmanmfg.com

SS-GCEC96

SS-GCEC96

www.goodmanmfg.com

5

Dimensions

Air  

Discharge

Air  

Return

Model

A

B

C

D

E

GCEC960403BNA

17½"

16"

13⅞"

12⅛"

13⅝"

GCEC960603BNA

17½"

16"

13⅞"

12⅛"

13⅝"

GCEC960803BNA

17½”

16”

13⅞”

12⅛”

13⅝”

GCEC961005CNA

 21" 

19½"

17⅜"

16"

17½"

A

34½

4⅛

11⅜

14¾

25⅛

28¾

C

6⅞

6⅞

11⅜

14⅞

14¾

25⅛

 2½

2

1⅞

2⅝

23

14

1⅜

1⅝

E

D

Unfolded Flanges

18⅛

Unfolded Flanges

20⅛

Folded Flanges

2⅝

 1⅞

2

Front View

Right-Side View

Low-Voltage

Electrical Outlet

Alternate  Gas

High-Voltage

Electrical Outlet 

Standard Drain Trap

Drain Trap Holes

Alternate 

Gas Supply  

Alternate Vent/

High-Voltage 

Electrical Outlet

Right Side Exterior

Drain Trap Holes

Low-Voltage 

Electrical Outlet

Air

Discharge

Air

Discharge

Folded Flanges

B

18¼

Minimum Clearances to Combustible Materials

Position

Sides

Rear

Front

Bottom

Flue

Top

Downflow

0"

0"

3"

NC

0"

1"

Horizontal

6"

0"

3"

C

0"

6"

C = If placed on combustible floor, the floor MUST be wood ONLY.

NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.

Summary of Contents for GCEC96

Page 1: ...down flow horizontal left or right Certified for direct vent 2 pipe or non direct vent 1 pipe Easy to install top venting with optional side venting Convenient left or right connection for gas and ele...

Page 2: ...ontrol Configuration NOx M Upflow Horizontal N Low NOx C Downflow Horizontal Cabinet Width Motor B 17 C 21 V Variable Speed ECM ComfortNet D 24 E Multi Speed ECM S Single Speed Maximum CFM 2 800 CFM 4...

Page 3: ...ipes The optional Combustion Air Pipe is dependent on installation code requirements and must be 2 or 3 diameter PVC Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size sho...

Page 4: ...ernate Gas High Voltage Electrical Outlet Standard Drain Trap Drain Trap Holes Alternate Gas Supply Alternate Vent High Voltage Electrical Outlet Right Side Exterior Drain Trap Holes Low Voltage Elect...

Page 5: ...78 1035 1002 964 ON ON ON Ylo 939 894 846 806 759 706 661 614 Y 1137 1096 1056 1018 981 940 897 859 CONTINUOUS FAN Dipswitch Setting S2 2 S2 3 S2 4 Static 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 Tstat Call CF...

Page 6: ...969 928 ON ON ON Ylo 1328 1287 1249 1215 1170 1131 1085 1046 Y 782 629 547 469 396 333 N A N A CONTINUOUS FAN Dipswitch Setting S2 2 S2 3 S2 4 Static 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 Tstat Call CFM CF...

Page 7: ...Ylo 1311 1293 1249 1203 1172 1122 1088 1041 Y 750 644 569 507 442 388 328 N A CONTINUOUS FAN Dipswitch Setting S2 2 S2 3 S2 4 Static 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 Tstat Call CFM CFM CFM CFM CFM CFM...

Page 8: ...73 ON ON ON Ylo 1866 1817 1774 1729 1684 1637 1593 1552 Y 1477 1422 1364 1301 1244 1190 1135 1078 CONTINUOUS FAN Dipswitch Setting S2 2 S2 3 S2 4 Static 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 Tstat Call CFM...

Page 9: ...BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800...

Page 10: ...GND INTERNAL TO SWITCH PRESSURE HIGH FIRE PROT DEVICE INTEGRATED CONTROL PK PU PLUG CONNECTION L N BK C DOOR OPEN OPEN WHEN DOOR SWITCH COMPARTMENT BLOWER SWITCH TEMP GND 1 BLOWER CIRCULATOR JUNCTION...

Page 11: ...5 CFSB21 Downflow Sub Base 21 RF000142 Drain Kit Horizontal Left Vertical Flue 0170K00000S Flush Mount Vent Kit 3 or 2 0170K00001S Flush Mount Vent Kit 2 AFE18 60A Fossil Fuel Dual Fuel Kit HASFK Hig...

Page 12: ...EC96 Goodman Manufacturing Company L P reserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2021 Goodman Manufacturing Comp...

Reviews: