Goodman CONDENSING UNIT HEAT PUMP Installation & Service Reference Download Page 24

24

Dia

gnos

ti

c

/Sta

tu

s

 LED Code

s

 

ComfortNet™ 

T

h

ermostat Onl

y

 

S

y

m

p

toms of 

A

b

normal 

Op

eratio

n

 (L

eg

a

c

y

 &

 

ComfortNet™ T

h

ermost

at) 

G

ree

Y

e

llow

 

R

ed 

R

ed Y

1

 

Fa

ult 

De

s

c

ript

ion 

Mess

ag

C

ode 

Possible Cau

se

s

 

C

o

rrect

iv

e A

cti

on

s

 

Not

e

s

 & Ca

utions

 

x

 

A

ir co

nd

iti

on

er/

h

e

a

pump

 may

 

app

ea

to

 be op

er

atin

g no

rmally

x

 

Int

egr

at

ed co

ntr

o

l modu

le 

dia

g

n

o

st

ic/

s

ta

tu

s LE

D

’s 

d

is

p

lay

 

the

 in

dic

a

ted 

co

de

OFF 9

 

Fla

s

he

s

 

OFF 

ON if call 

p

res

en

t;

 

OFF if no 

call 

x

 Low

 P

ilot 

Vo

ltag

e

 

LO

SECO

ND 

VOL

09 

x

 Contr

o

de

te

cts

 

s

e

co

nd

ar

y

 v

o

lt

a

ge 

le

ss

 

th

an

 18

 VAC.

 

x

 Tr

a

n

sfor

me

ov

erloa

d

ed

x

 

Low

 line

 v

o

ltag

e. 

x

 Ch

e

c

k

 fu

se

x

 C

o

rre

ct 

low

 

s

e

co

nd

ar

y

 v

o

lt

a

ge 

con

dit

io

n

x

 C

h

ec

tr

a

n

sf

orm

e

r; 

rep

la

c

e if ne

ed

ed.

 

x

 Tu

rn

 p

o

w

e

OFF 

pri

o

r t

o

 re

pai

r. 

x

 

Fault 

w

ill cle

ar if 

s

e

co

nd

ar

y

 v

o

lt

a

ge 

ris

es ab

ov

21V

A

C

x

 

Re

p

lac

e w

it

h

 co

rr

e

c

re

pl

ac

e

m

en

t p

a

rt

(s

).

 

x

 

Compre

s

s

o

r is

 of

f.

 

x

 

Int

egr

at

ed co

ntr

o

l modu

le 

dia

g

n

o

st

ic/

s

ta

tu

s LE

D

’s 

d

is

p

lay

 

the

 in

dic

a

ted 

co

de

OFF 

ON 

ON 

ON if call 

p

res

en

t;

 

OFF if no 

call 

x

 Co

mp

 

Pr

o

tec

to

O

pen 

Not 

dis

p

lay

ed 

Not 

dis

p

lay

e

x

 

N

o

 cu

rr

ent

 th

ro

ug

h r

u

or sta

rt 

w

indi

n

g

s

x

 

 Co

mp

re

ss

or

 ru

n

 

w

inding is op

en

x

 Compre

s

s

o

n

o

p

rop

er

ly

 w

ir

e

d

 t

o

 

con

tr

o

l. 

x

 F

aulty

 comp

re

ss

o

wi

ri

n

g

x

 

F

a

ile

d c

o

mp

re

ss

o

r r

un 

cap

ac

ito

r. 

x

 

F

aulty

 run

 ca

pa

cit

o

wi

ri

n

g

 

x

 Chec

c

o

mp

re

ss

o

r; 

rep

a

ir

/r

epl

ac

e as 

n

e

ed

ed

x

 Ch

e

c

k

 w

iring

rep

a

ir

/r

epl

ac

e as 

n

e

ed

ed

x

 Ch

e

c

k

 ru

c

a

pa

ci

to

r;

 r

e

p

lac

as ne

ed

ed. 

x

 Tu

rn

 p

o

w

e

OFF 

pri

o

r t

o

 re

pai

r. 

x

 

Fault 

w

ill cle

a

r aft

e

1

 no

rm

al

 c

y

c

le

x

 

F

ault m

a

y

 be 

cle

a

re

d by

 cy

cling

 

24V

A

C

 to 

co

ntr

o

l.

 

x

 

Re

p

lac

e w

it

h

 co

rr

e

c

re

pl

ac

e

m

en

t p

a

rt

(s

).

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODES

Summary of Contents for CONDENSING UNIT HEAT PUMP

Page 1: ...the 10 Year Unit Replacement Limited Warranty and the 10 Year Parts Limited Warranty for Goodman branded products online registration must be com pleted within 60 days of installation Online registrat...

Page 2: ...for the unit s is the angle to obstructions Either side adjacent the valves can be placed toward the structure provided the side away from the structure maintains minimum service clear ance Corner in...

Page 3: ...ant tubing clean and dry prior to and during installation Tubing should always be cut square keeping ends round and free from burrs Clean the tubing to prevent contamination Do NOT let refrigerant lin...

Page 4: ...ean any copper oxide present from the inside of the refrigerant lines and spread it throughout the system This may cause a blockage or failure of the metering device 3 After brazing quench the joints...

Page 5: ...CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH DUE TO ELECTRIC SHOCK WIRING MUST CONFORM WITH NEC OR CEC AND ALL LOCAL CODES UNDERSIZED WIRES COULD CAUSE POOR EQUIPMENT PERFORMANCE EQUIPMENT DAMAGE O...

Page 6: ...ING THERMOSTAT 1 2 R C B L U E R E D W H T B L K INDOOR UNIT Communicating Thermostat with Low Voltage Wires to Heat Pump NOTE If the heat pump unit is wired in the communicating mode together with th...

Page 7: ...L R G W BL BR G W2 C R G W BL INDOOR UNIT 18 GA 7 WIRE NEEDED WHEN TWO OT ARE USED SEE NOTE 4 RED GREEN WHITE BLUE C W2 O Y1 Y2 G R E O Y1 Y2 HEAT PUMP W2 C R TYP H P ROOM THERMOSTAT 18 GA 7 WIRE SYST...

Page 8: ...or 10 minutes for fixed orifices and 20 minutes for expansion valves CHARGE VERIFICATION REFRIGERANT UNDER PRESSURE DO NOT OVERCHARGE SYSTEM WITH REFRIGERANT DO NOT OPERATE UNIT IN A VACUUM OR AT NEGA...

Page 9: ...e cleared by depressing the button for greater than five seconds Consecutively repeated faults are displayed a maximum of three times Refer to the fault code definitions at the end of this manual for...

Page 10: ...ooling Heating M odels CTK0 AAWIRING NOTE Refer to section Electrical Connections High Voltage Connections for 208 230 volt line connections to the air conditioner or heat pump NOTE A removable plug c...

Page 11: ...first sub menu is then displayed See tables below for listing of furnace sub menus Touch the or _ to step through the list of submenus and view settings If a setting can be adjusted _ and keys will a...

Page 12: ...itioner or heat pump model number Serial Number SER NUM Displays the air conditioner or heat pump serial number Optional Software SOFTWARE Displays the application software revision IDENTIFICATION Sub...

Page 13: ...econds Selects the indoor blower heat OFF delay applies to heat pump only Defrost Interval DEFROST 30 60 90 or 120 minutes default is 30 minutes Selects the time interval between defrosts applies to h...

Page 14: ...t the network may arise The integrated control module has some on board tools that may be used to trouble shoot the network These tools are red communications LED green receive Rx LED and learn button...

Page 15: ...blocks are securely twisted together prior to inserting into terminal block Verify heat pump installation type legacy traditional or communicating Check data 1 data 2 voltages Rapid Flashing Normal ne...

Page 16: ...ED SUCTION PRESSURE TEMPERATURE CHART SATURATED SUCTION TEMPERATURE F LIQUID PRESSURE PSIG R 22 R 410A 200 101 70 210 105 73 220 108 76 225 110 78 235 113 80 245 116 83 255 119 85 265 121 88 275 124 9...

Page 17: ...Faulty Evap Fan Motor Repair or Replace Shorted or Grounded Fan Motor Test Motor Windings Improper Cooling Anticipator Check Resistance of Anticipator Shortage of Refrigerant Test For Leaks Add Refrig...

Page 18: ...e indicated code 6 Flashes ON OFF OFF x Board miss operation INTERNAL FAULT EE x Compressor relay contacts welded x Replace control x Turn power OFF prior to repair x Replace with correct replacement...

Page 19: ...emory card x Error code will be cleared once data is loaded Applies only to fully communicating system using ComfortNet thermostat x Air conditioner heat pump fails to operate x Air conditioner heat p...

Page 20: ...indoor blower motor repair replace as needed x Check indoor thermostat setting x Turn power OFF prior to repair x Fault will clear after 30 consecutive normal cycles x Fault may be cleared by cycling...

Page 21: ...tdoor fan motor capacitor replace as needed x Turn power OFF prior to repair x Replace with correct replacement part s x Compressor and outdoor fan are off x Low pressure switch trip 3 times within sa...

Page 22: ...ompressor repair replace as needed x Check compressor wiring repair replace as needed x Turn power OFF prior to repair x Fault will clear after 1 normal cycle x Fault may be cleared by cycling 24VAC t...

Page 23: ...all x Open Run Circuit Lockout OPEN RUN LOCK 07 x Compressor run winding is open x Compressor not properly wired to control x Faulty compressor wiring x Check compressor repair replace as needed x Che...

Page 24: ...prior to repair x Fault will clear if secondary voltage rises above 21VAC x Replace with correct replacement part s x Compressor is off x Integrated control module diagnostic status LED s display the...