13
A
IR
C
ONDITIONER
/H
EAT
P
UMP
A
DVANCED
F
EATURES
M
ENUS
(
CONT
’
D
)
Submenu Item
Indication (for Display Only; not User Modifiable)
Mode (MODE)
Displays the current air conditioner operating mode
CFM (CFM)
Displays the airflow for the current operating mode
STATUS
Submenu Item
User Modifiable Options
Comments
Heat Airflow Trim
(HT TRM)
-10% to +10% in 2% increments,
default is 0%
Selects the airflow trim amount; applies to
heat pump only.
Heat ON Delay
(HT ON)
5, 10, or 15 seconds, default is 5
seconds
Selects the indoor blower heat ON delay;
applies to heat pump only.
Heat OFF Delay
(HT OFF)
30, 50, 70, or 90 seconds, default
is 30 seconds
Selects the indoor blower heat OFF delay;
applies to heat pump only.
Defrost Interval
(DEFROST)
30, 60, 90, or 120 minutes, default
is 30 minutes.
Selects the time interval between defrosts;
applies to heat pump only.
Compressor Delay
(CMP DLY)
0, 5, 15, or 30 seconds, default is 5
seconds
Selects the compressor off time after a
reversing valve shift; applies to heat pump
only.
HEAT SET-UP
T
HERMOSTAT
M
ENU
If this heat pump is installed with a CT compatible furnace, the system is recognized as a dual fuel system. The balance point
temperature should be set via the thermostat advanced menu. Navigate to the
THERMOSTAT
menu. Press the
INSTALLER
CONFIG
key. Navigate to the
SETUP
menu and press the
INSTALLER CONFIG
button. Navigate to
dF BAL PNT
. Adjust the
dual fuel system balance point using the back/forward arrows.