To make a call the visitor should press the push button corresponding to the apartment he wishes to

contact. An acoustic tone will be heard confirming the call is in progress once the push button has

been pressed

. At this moment the call will be received at the

and the door panel led will turn on

monitor (telephone) in the dwelling. During the call the visitor can correct his call by pressing a push

button corresponding to a different apartment, in which case the original call is cancelled.

O

In systems with several accesses doors, the other(s) door panel(s) will be automatically disconnected:

If a visitor tries to call from other door panel an acoustic tone will be heard and the door panel

led   will be on

.

confirming the system is busy

O

General door panel (EL501 mode): If the call is made from the general door panel, the inner door

panel of the building called and other possible general door panel will remain automatically

disconnected, if another visitor tries to call from an inner busy door panel an acoustic tone will be

heard

confirming the system is busy or from another general door

and the door panel led will be on

panel, an acoustic tone will be

confirming the system is busy and

heard

the general door panel led

will blink for 3 seconds. The door panels of the others inner buildings will remain free to be used.

O

General door panel (EL501 mode): In the case that the call is made from an inner door panel, the rest

of inner door panels will remain free to be used. From general door panels only will be able to make

calls to the inner buildings whose door panels are not in use, if the visitor tries to make a call to a busy

inner door panel, an acoustic tone will be heard confirming the system is busy and the general door

panel

will blink for 3 seconds

led

.

O

The call lasts for 45 seconds, during which time an image appears on the apartment's monitors for 2

seconds after the call is received without the visitor knowing, and the status LED on the master monitor

will illuminate (green). If the call is not answered within 45 seconds, the master monitor's status LED

will illuminate (red), LED on the door panel will turn off and the channel will be free.

O

To establish communication, lift the handset of the monitor (telephone), and the monitor's status LED

(green) and the door panel's LED will illuminate

.

O

The communication will last for one and a half minutes or until the handset is replaced. After the

communication, the monitor's status LED will illuminate (red), the door panel's LED will turn off and

the channel will be free.

O

To open the door, press the door release push button during call or communication progresses: with

one press, the door release operates during 3 seconds. During the lock release activation an acoustic

tone will be heard on the door panel confirming the lock release is activated and the led

will also

turn on for 3 seconds.

SYSTEM OPERATION

76

DOOR PANEL DESCRIPTION

Sound module

EL63 Plus P/T

2

EL64 Plus

2

D

oor panel description.

Push buttons electronic module

EL610D

Short connection cable, It is supplied with EL610D module (16 cm length).

, for 5 single push-buttons or 10 double push buttons.

, on video systems with color camera.
, on audio systems.

Connection cable RAP-610D (27 cm length).

General detail of parts, for assembly the door panel.

Aluminium modules

Electronic

modules

Frame modules

Embedding boxes

Push buttons module

Main module

Door panel description.

For the connection of the push-buttons between the sound module and the push

buttons module EL610D and between push-buttons modules EL610D.

For the connection of the push-buttons between the sound module and the push

buttons module EL610D and between push-buttons modules EL610D.

This cable is necessary when the distance between modules to connecting is

greater due to the distribution of these modules in the door panel/s.

Bus Nexa connection cable e th

(l ng 50 cm).

For the connection of the

or

modules with others Bus

EL632 Plus P/T

EL642 Plus

Nexa modules (see page

).

83

Uno system:

O

Tekna Uno monitor

T-540 Uno telephone are fully compatible with Tekna Plus monitor

T-

and

and

540 Plus telephone. However,

a Uno communications resistor must be setting with the

SW1 configuration dip switch of the door panel,

see

85 .

(

page

)

O

If the distance from the door panel to the farest monitor or telephone is longer than 200 meters, or
the building has more than 200 apartment units, a

repeater must be installed.

RDPlus/Uno SE

IMPORTANT NOTICE

IMPORTANT NOTICE

Summary of Contents for Plus Nexa

Page 1: ...Plus Nexa Code 50122328 Instructions manual Audio and Video door entry system One or several accesses doors General door panel T632 PLUS N P T E rev 0118...

Page 2: ...e Golmar RAP 5130 In installations no longers than 100m cable can be used Introduction 73 Index 73 Starting recommendations 73 Safety precautions 74 System characteristics 74 Important notice 75 Syste...

Page 3: ...l 50123594 O Telephone T540 Plus SE Description installation configuration and programming of the telephone see manual T540 PLUS SE C d 50122199 disponible en https doc golmar es search manual 5012219...

Page 4: ...ls are not in use if the visitor tries to make a call to a busy inner door panel an acoustic tone will be heard confirming the system is busy and the general door panel will blink for 3 seconds led O...

Page 5: ...es Embedding boxes Push buttons module Main module Door panel description For the connection of the push buttons between the sound module and the push buttons module EL610D and between push buttons mo...

Page 6: ...Audio input communication Twisted pair video signal input Twisted pair video signal output Coaxial shield Video signal coaxial input Video signal coaxial output Color camera only EL632 PLUS module P...

Page 7: ...ons electronic module EL610D description Front side Push buttons module x10 Configuration dip switch Push buttons call code Push button number Input Output push buttons connector x3 Back side MODULES...

Page 8: ...door panel The door panel has been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality...

Page 9: ...placement Sound module EL632 Plus P T EL642 Plus Push buttons electronic module EL610D Frame If there is push buttons module repeat the above process locating under the sound module as shown in the d...

Page 10: ...tons EL610D module as shown in the drawing Between push buttons modules EL610D of different embeddingt boxes insert the short connection cable in the low connector of the last module EL610D of the fir...

Page 11: ...Off Off On Off Off Off Off On On On On On On On Off Off Off Off Off On Off Off Off Off Off Off Off On Off Off On Off Off Off Off Off Off Off On Off Off On Off Off Off Off Off Off Off Off Off Off Off O...

Page 12: ...d to the system with control manu l a TCode C Nexa A NFC EL3002 Con ect M xim 2 n to power the illumination module a um EL3002 modules CD NEXA BT Con ect n to the module to add to the system with a co...

Page 13: ...led will turn on during the call time process During communication The led will turn on during communication process During door release The led will turn on during door release End of communication T...

Page 14: ...panel if exists set the rest to OFF Set to ON so that the volume tone emitted by the door panel call reception busy system and lock release are or placed to OFF if a HIGH LOW volume tone is desired U...

Page 15: ...monitor telephone manual see page 74 for manual web link In general door panel EL501 mode set to ON for general door panel push buttons programming or backbone building monitor telephones The program...

Page 16: ...lly programmed Repeat these steps to program the rest of push buttons Once the programming has been finished set to OFF the programming switch If you don t the general door panel will reproduce a tone...

Page 17: ...t the switch 2 to ON to show that the system is ready for programming the general door panel will reproduce a tone Press the general door panel push button that is wished has this monitor telephone co...

Page 18: ...step Programming the monitors and telephones from a general door panel Description of the function connector CN3 The function connector Cn3 is located at the upper left side of the back of the sound m...

Page 19: ...iring configuration and final adjustments fix the frame in the embedding box with the supplied screws Close the frame If after starting the system it s considered that the audio volume isn t correct p...

Page 20: ...echanical assembly for double door panel and once finished the adjustments stick the adhesive gasket that is supplied with the push buttons module in the rod of joining modules If the door panel to in...

Page 21: ...at can be connected to a FA Plus C power supply is 10 and 50 units in case of a FA Plus model Link power supplies to connect more units than the specified as it s shown on page 105 If the lock release...

Page 22: ...1 D2 D2 D4L PLUS D4L PLUS JP1 JP1 S S M D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 Main Place this power supply as closest as possible to the first distributor Take off JP...

Page 23: ...Copper core Copper shield ELECTRICAL CHARACTERISTICS Nominal capacitance Characteristic impedance VALUES Velocity of Propogation Access door panel The installation diagram shows the connection of a vi...

Page 24: ...T Vpi Vd1 Mpi Md1 _ _ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 Place this power su...

Page 25: ...video system with one or several door panels for the same building If the system has one access door panel only override the wiring to the second door panel If the system has more than one access doo...

Page 26: ...a Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 Main Place this power supply as closest as possible to the first telephone Access door panel M Master S Slave Lock release Vd c A _ D...

Page 27: ...out CV1 CV2 Lock release Vd c Access door panel The installation diagram shows the connection of an audio system with one or several door panels for the same building If the system has one access doo...

Page 28: ...ter S Slave BACKBONE 0 E S S1 D4L PLUS JP1 FA Plus o FA Plus C SEC PRI FA Plus C SEC PRI 230 110 0 M D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 Lock...

Page 29: ...door panel GENERAL DOOR PANEL BACKBONE 0 E S S1 D4L PLUS JP1 SEC PRI FA Plus o FA Plus C FA Plus C SEC PRI 230 110 0 M D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 D Malla Vin Ain Aout Vin Vout Vout...

Page 30: ...s and up to 120 inner door panels backbones buildings In case of more than two door panels wire them as the second is conected In video systems use a D4L Plus distributor before each inner building ex...

Page 31: ...ct our technical support department 1 50mm 2 50mm 0 25mm 0 25mm CAT 5 RG 59 Terminal SECTIONS CHART 100m Distance 300m A A A D in out V V in out V V V V in in out out CV1 CV2 RG 59 CAT 5 Coaxial Sw1 3...

Page 32: ...out Vin Vout Vout CN1 CV1 CV2 D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 To telephones Main Main General door panel Inner door panel BACKBONE 1 EL501 mode EL500 mode BACKBONE 0 M Master S Slave 10...

Page 33: ...ontact our technical support department CV1 CV2 Main IMPORTANT NOTES To install and configure properly do always follow the enclosed information The installation diagram shows the connection of an aud...

Page 34: ...equired quantity The first power supply should be connected to the door panel and to the first group of monitors or telephones connect the next groups to the positive terminal of its corresponding pow...

Page 35: ...ws to exit from the building being not necessary the use of a key Door panel Lock release Vd c Main To monitors Main Connection to the synthese vocale module of FDI for France Lock release Vd c 106 OP...

Page 36: ...ion progresses w The CV1 and CV2 terminals for door opening are voltage free outputs The cable requires a connection depending on whether 12Vdc or 12Vac is needed page to page 105 93 104 w Make a shor...

Page 37: ...108 NOTAS NOTES...

Page 38: ...NOTAS NOTES 109...

Page 39: ...110 NOTAS NOTES...

Page 40: ...e provocar interferencias da inas y 2 debe aceptar cualquier interferencia recibida incluyendo las que pueden provocar un funcionamiento no deseado NOTE Operation is subject to the following condition...

Reviews: