103
INSTALLATION DIAGRAMS
FA-Plus o FA-Plus/C
SEC
PRI
~
~
+ +
-
-
FA-Plus/C
SEC
PRI
230
-
-
110 0
+ +
S
D
Malla
V
in-
A
in
A
out
V
in+
V
out-
V
out+
CN1
+
- +
CV1
CV2
-
D
Malla
V
in-
A
in
A
out
V
in+
V
out-
V
out+
CN1
+
- +
CV1
CV2
-
To telephones
Main
Main
General door panel
Inner door panel
BACKBONE 1
EL501 mode
EL500 mode
BACKBONE 0
M =Master.
S =Slave.
10
1
9
2
8
3
7
4
6
5
CN3
10
1
9
2
8
3
7
4
6
5
CN3
M
Lock release
Vd.c.
Lock release
Vd.c.
SW2
SW1
SW1
SW2
104
GENERAL DOOR PANEL
SEC
PRI
~
~
+ +
-
-
FA-Plus o FA-Plus/C
D
Malla
V
in-
A
in
A
out
V
in+
V
out-
V
out+
CN1
+
- +
CV1
CV2
-
To telephones
A
udio installation with general door panel
to large residential complexes.
1,50mm²
2,50mm²
0,25mm²
0,25mm²
Terminal
SECTIONS CHART
100m.
Distance
300m.
A , A , A, D
in
out
For greater distances contact our technical support department.
+, , CV1, CV2
–
Main
IMPORTANT NOTES:
To install and configure properly, d
o always follow the enclosed information.
The installation diagram shows the connection of an audio system with one general door panel
and up to 120 inner door panels (backbones/buildings).
In case of more than one general door panel, wire them as it shows in the video installation
diagram, (see page 99).
BACKBONE 120
Inner door panel
EL500 mode
10
1
9
2
8
3
7
4
6
5
CN3
M
Lock release
Vd.c.
SW1
SW2