78
POWER SUPPLY INSTALLATION
LOCK RELEASE INSTALLATION
nstalling the FA-805 power supply.
I
DIN 46277
77
DOOR PANEL INSTALLATION
lace the nameplate labels.
P
Open the label holder.
Place the label and
close.
lose the door panel.
C
inal adjustments.
F
If after starting the system it's considered that the audio
volume isn't correct, proceed with the necessary
adjustments as shown.
The telecamera has a pan and tilt mechanism built in to adjust
the telecamera position.
In case of low light conditions, an external illumination can be
activated by connecting a SAR-12/24 relay between
terminals '+H' and 'L2' of the sound module.
Fix the door panel by using the supplied
screws.
Finish the door panel assembly by pressing the
closing heads.
The power supply must be installed in a dry and
protected place. It's recommended to protect the
power supply by using a thermo-magnetic circuit
breaker.
To install the power supply directly on the wall, drill two holes of
Ø6mm. and insert the wallplugs. Fix the transformer with the
specified screws.
The power supply can be installed on a DIN 46277 guide
simply pressing it. To disassemble the power supply
from the DIN guide, use a plain screwdriver to lever
the flange as shown on the picture.
The FA-805 power supply uses 6 units over DIN guide.
Remember to protect the input terminals with the supplied cover.
ock release installation.
L
If the lock release will be installed in a metal door, use a
Ø3,5mm.
drill and tap the hole. In case of wood door, use a Ø3mm. drill.
IMPORTANT: the lock release must be of 12Vd.c. or a.c.
See page 92 (a.c. lock releases) and page 93 - 96 (d.c lock releases)
3,5 x 45
DIN-7971
3,5 x 45
DIN-7971
M 4 x 8
3,5 x 25
DIN-7972
DIN-963