Microprocessed system with 3 common wires plus coaxial cable installation or 4 common wires plus 
twisted pair (only for kits /SC).
Fully compatible with 'Stadio' audio systems of 4 common wires installation.
Unlimited number of door panels being not necessary the use of switching units.
EL560 module for video installations with twisted pair cable, integrated in EL500SE circuit.

O

Communications resistor for the system UNO or PLUS, integrated in EL500SE circuit.
Acoustic busy channel and call acknowledgement signals.
Door opening timed at 3 seconds.

O

Input for external door release push button (timed at 3 or 15 seconds).

O

a.c or d.c lock release operated by relay.

Up to 2 monitors and 1 telephone in the same apartment without additional power supplies.

With T-940 Plus telephones:

w

Privacy on audio communications.

w

Three-position control for call volume: maximum, medium and minimum.

w

Intercommunication function with other monitor or telephone of the same apartment.

w

Input for external door bell push button.

w

Output for additional call repeater.

w

Call to a master porter's exchange.

w

Panic call to the porter's exchange.

w

Different call reception tones depending where the call is comming from: main or slave door 

panels, door bell push button, intercom, ...

O

With T-740 Plus telephones, addition to the above features:

w

Three-position control for call volume: maximum, medium and off.

w

Input for external door release push button.

w

Allows one of these functions at once, Configuration with dip switch  Sw1 (see page 89):

w

"Autoswitch-on" function.

w

Output for auxiliary relay activation (18Vdc/0,5 A maximum).

w

Call to a slave porter's exchange.

w

Intercommunication function with other monitor or telephone of the same apartment.

69

Introduction........................................69
Index .................................................69
Starting recommendations....................69
Safety precautions ...............................70
System characteristics ..................70 to 71
System operation.................................71

Important notice

............................71

Door panel installation.............................

Embedding box positioning ................72
Door panel fixing ..............................73
Push buttons wiring............................74
Door panel settings ....................75 to76
Final adjustments ..............................77

Power supply installation.......................78
Lock release installation .......................78
Tekna Plus monitor...................................

Description ......................................79
Function push buttons........................80
EL562 module..................................81
End of line resistor .............................81
Monitor connector description ............82
Monitor installation ...........................83
Programming ...................................84

T-940 Plus telephone ...............................

Description ......................................85
Function push buttons........................85

Telephone installation........................86
Programming ...................................87

T-740 Plus telephone ...............................

Description ..............................88 to 89
Function push buttons........................89
Telephone installation........................90
Programming ...................................91

Installation diagrams ...............................

Connection of an a.c. lock release.......92
Sections charts..................................92
Video installation with coaxial .....93 to 94
Video installation without coaxial 95 to 96

Optional connections ..............................

External lock release activation ...........97
Aux. devices activation with Tekna Plus .97
2nd camera activation .......................98
TV connection ..................................98
Intercom ..........................................99
External lock release with T740Plus......99
Aux. devices activation with T740 Plus100
Door bell push button connection......100

Troubleshooting hints.........................101
Notes...............................................102
Compliance .....................................103

INTRODUCTION

INDEX

First of all we would like to thank and congratulate you for the purchase of this product manufactured by 
Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification 
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the 
legion of features this system offers. To obtain the maximum profit of these features and a properly wired 
installation, we kindly recommend you to expend a few minutes of your time to read this manual.

STARTING RECOMMENDATIONS

O
O
O

O

O

Do not use excessive force when tightening the power supply connector screws.
The entire installation must be at least 

40cm

. away from any 

other installation

.

Before to connect the system, check the connections between door panel, monitors, telephones, and 
the transformer connection. Do always follow the enclosed information.
Each time the power supply is restarted, or after a modification, the system will remain blocked during 
30 seconds.
Always use RG-59 B/U MIL C-17 or RG-11 coaxial cables, (see page 92). 

Never use coaxial 

antenna cable.

 In installations no longers than 100m., 

Golmar RAP-5130

 cable can be used.

SAFETY PRECAUTIONS

SYSTEM CHARACTERISTICS

O
O
O
O

w
w
w
w
w

O

w
w
w

O

O

Install or modify the equipment 

without the power connected

.

The installation and handling of these equipments must be performed by 

authorised personnel

.

The entire installation must be at least 

40 cm

. away from any 

other installation

.

With power supply:

w

Do not use excessive force when tightening the connector screws.
Install the power supply in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
Do not block ventilation holes of the unit so that air can circulate freely.
To avoid damage, the power supply has to be firmly fixed.
To avoid an electrical shock, neither remove the protection cover nor handle the connected wire in 

the terminals. 

With monitor, telephones and distributor:

Do not use excessive force when tightening the connector screws.
Install the power supply in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.

w

Do not block ventilation holes of the equipments so that air can circulate freely.

Remember, the installation and handling of these equipments must be performed by authorized 
personnel and in the absence of electrical current.
Do always follow the enclosed information.

Continue

Summary of Contents for 50124545

Page 1: ...Stadio Plus Video Kit digital installation Instructions manual T5000ML rev 0113 Cód 50124545 ...

Page 2: ...0 Plus100 Door bell push button connection 100 Troubleshooting hints 101 Notes 102 Compliance 103 INTRODUCTION INDEX First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our customers is stated through the ISO 9001 certification and for the manufacturing of products like this one Its advanced te...

Page 3: ...hese functions at once Configuration with dip switch Sw1 see page 89 w Autoswitch on function wOutput for auxiliary relay activation 18Vdc 0 5 A maximum wCall to a slave porter s exchange wIntercommunication function with other monitor or telephone of the same apartment SAFETY PRECAUTIONS SYSTEM CHARACTERISTICS O O O O w w w w w O w w w O O Install or modify the equipment without the power connect...

Page 4: ...ne handset The communication will last for one and a half minutes or until the handset is replaced Once the communication has finished the system will be freed O To open the door press the door release push button during call or communication progresses with one press the door release operates during 3 seconds During the lock release activation an acoustic tone will be heard on the door panel conf...

Page 5: ...he door panel has been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry systems avoid direct incidence from light sources Pass the wiring through the hole made in the bottom part of the embedding box Level and flush the embedding box Once the embedding box...

Page 6: ...anel this selection should ease the door panel wiring The opening direction will be settled through the hinges position that must be passed through the header clips as shown For example if the hinges are placed on both clips of the lower header the door panel will open downwards if they are placed on the right clips of both headers the door panel will open to left To hold the door panel on the emb...

Page 7: ...on of push buttons The CP terminal must be connected to the push buttons common terminal Link the push buttons inputs P1 and P8 to the push buttons as shown in the example CN6 CP P8 B P7 P1 P6 P2 P5 P3 P4 Top view CP Black B Red P1 Green P2 Orange P3 Blue P4 Violet P5 Yellow P6 White P7 Brown P8 Grey Colours codes EL500SE Description CN6 connector Push button 1 Push button 2 only two ways kits CP ...

Page 8: ...the backbone installation or in the general door panel if exists set the rest to OFF Set to ON so that the volume tone emitted by the door panel call reception busy system and lock release are HIGH or placed to OFF if a LOW volume tone is desired Uno System proper system operation set to ON only in the closest door panel to the backbone installation placed the rest to OFF With digital repeater RD ...

Page 9: ...ems with general door panel this function can be activated in one door panel of each inner backbone building Set to ON for monitor or telephones programming Once the programming progress is finished return the switch to OFF position The programming process is described on pages 84 monitors 87 and 91 telephones Set to OFF in case of a master door panel Each system must have only one master door pan...

Page 10: ... isn t correct proceed with the necessary adjustments as shown The telecamera has a pan and tilt mechanism built in to adjust the telecamera position In case of low light conditions an external illumination can be activated by connecting a SAR 12 24 relay between terminals H and L2 of the sound module Fix the door panel by using the supplied screws Finish the door panel assembly by pressing the cl...

Page 11: ...nstalled on a DIN 46277 guide simply pressing it To disassemble the power supply from the DIN guide use a plain screwdriver to lever the flange as shown on the picture The FA 805 power supply uses 6 units over DIN guide Remember to protect the input terminals with the supplied cover ock release installation L If the lock release will be installed in a metal door use a Ø3 5mm drill and tap the hole...

Page 12: ...ositions call reception volume control Cable slot Contrast control color control in case of color screen Brightness control escription of the Tekna Plus monitor D a f g b j l k m c I h e d 00000000000 xx MASTER INTER A1 SLAVE CODE ESCALERA STAIR PISO FLOOR PUERTA DOOR ATENCIÓN Alta tensión No abrir la tapa Manipular sólo por personal del servicio técnico WARNING High voltage Don t open cover Handl...

Page 13: ...exchanges that have enabled the reception of this type of call If not allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation Second camera activation and call to a slave porter s exchange functions require an internal modification of the monitor If any of these functions are required contact with your nearest authorized ...

Page 14: ...500SE microprocessed circuit must be setting with SW1 3 to ON page 75 Refer to the specific installation diagram The end of line jumper is placed on the CN4 connector that can be located on the monitor base In case of twisted pair cable installations the end of line jumper is placed in the El562 module also located in the CN4 connector of the monitor base Do not remove the jumper on monitors where...

Page 15: ...2 c Vertical wiring input d Attachment clip e Wiring input hole f Installation terminals positive ground video signal coaxial input coaxial shield video signal coaxial output audio communication digital communication door bell push button input intercom auxiliary calling device output video distributor activation output 2nd camera activation output optional device activation output twisted pair vi...

Page 16: ...height roughly The minimum distance between the monitor connector and the closest object must be 5cm Place the monitor at right angles to the connector and align the attaching holes of the monitor with the attachment hooks of the connector as it is shown on the drawing Lock out the monitor Press the right side till the attachment clip locks the monitor firmly To disassemble the monitor from the co...

Page 17: ...on the monitor At this moment the door release push button can be released Lift the handset to establish audio communication with the door panel Press the door panel push button that will call to this monitor At this moment the door panel will reproduce a tone and the monitor led will blink To program the monitor as Master switch it off and on again To program it as Slave press the door release pu...

Page 18: ...ne cord connector that allows to control the call reception level volume On Off push button After any telephone reset and during the next 45 seconds all the telephone functions will be disabled with the exception of call reception This push button allows to make an intercom call when the handset is not on the craddle This function is described on page 99 If the handset is on the craddle sends a pa...

Page 19: ...d to place the telephone near to heating sources in dusty locations or smoky environments The telephone can be fixed using an electrical embedding box or directly on the wall as shown on the picture If the telephone will be installed directly over the wall drill two holes of Ø6mm on the specified positions using 6mm wallplugs and Ø3 5 x 25mm screws Pass the installation wires through the correspon...

Page 20: ...Lift the handset to establish audio communication with the door panel With the door release push button pressed switch on the telephone Press the door panel push button that will call to this telephone At this moment the door panel will reproduce a tone and the telephone led will blink To program the telephone as Master switch it off and on again To program it as Slave press the door release push ...

Page 21: ...h button Volume control Subjection Door f h i all volume control C MAX OFF The telephone allows to regulate the call volume with a maximum medium and off value With the help of the switch of three positions placed in the right front of the telephone Positive ground SAV 90 Audio digital communication Connection to external door release push button Door bell push button input Auxiliary calling devic...

Page 22: ...sabled if a communication is already established PA output mode switches 1to ON and 2 to OFF Regardless of the handset s position it activates the PA telephone output C mode switches 1 to OFF and 2 to ON With the handset off the cradle allows to call to a porter s exchange that it is configurated as slave all to a slave porter s exchange mode switches 1 and 2 to OFF With the handset off the cradle...

Page 23: ...rams lose the telephone as shown on the picture Once the telephone is closed connect the handset using the telephone cord and put it on the cradle Avoid placing the telephone near sources of heat in dusty locations or smoky environments The telephone can be fixed using an electrical embedding box or directly on the wall as shown on the picture If the telephone will be installed directly over the w...

Page 24: ...it only in case of parallel units configure them as slaves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set to OFF the programming switch If you don t the door panel will reproduce a tone to advise that the system is still into programming mode To progr...

Page 25: ...0SE Va c Lock release ections chart S 1 00mm 2 50mm 0 25mm 0 25mm CAT 5 RG 59 Terminal SECTIONS CHART 50m Distance 150m A A A D in out V V in out V V V M in out p d p d CV1 CV2 RG 59 CAT 5 Coaxial Sw1 3 Off Twisted pair Sw1 3 On Note has a consumption greater than 0 8A use the installation mode with TF 104 transformer maximum consumption 1 5A If the alternating current lock release oaxial cable ch...

Page 26: ... _ D Malla Vin Vout CN4 A _ D Malla Vin Vout CN4 A _ D Malla Vin Vout CN4 A _ D Malla Vin Vout CN4 JP1 Main FA 805 Access door panel D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW1 SW2 SEC PRI 230110 0 M Master S Slave S ...

Page 27: ...ion example Remove JP1 jumper on all the video distributors and monitors see page 81 except on the ones where the video cable finishes don t use the video output IMPORTANT If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the rest of panels as shown on the diagram Access door panel A _ D Malla Vin Vout CN4 FA 805 D Ma...

Page 28: ...d1 _ _ A D CT Vd2 Md2 _ A D VpoMpo _ D6l Plus 2H EL562 JP1 Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 Main FA 805 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW1 SW2 SEC PRI 230110 0 Access door panel M Master S Slave S ...

Page 29: ...he video distributors and EL562 monitor modules see page 81 except on the ones where the twisted pair cable finishes don t use the video output Distributed installation example IMPORTANT If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the rest of panels as shown on the diagram Vp Mp A D _ EL562 JP1 FA 805 D Malla Vi...

Page 30: ...e lock release can be activated at any moment by using an external push button that must be connected between AP and terminals of the door panel Door opening timed at 3 or 15 seconds with the help of the dip switch SW1 2 see page 75 This function will allows to exit from the building being not necessary the use of a key To activate auxiliary devices the use of a SAR 12 24 relay unit will be requir...

Page 31: ...ence of the handset position If this device is shared for all the Tekna Plus monitors link their 2C terminal and use just one relay unit In case that each monitor has its own camera use a SAR 12 24 relay unit for each monitor and don t link the 2C monitor terminals This push button can be used to activate other auxiliary devices as the 2C terminal is used Usual applications are the surveillance of...

Page 32: ...cribed on pages 84 87 and 91 In case to intercom one monitor with one telephone configure the monitor as master Link the INT terminal of the units as it is shown on the enclosed diagram To establish an intercom communication lift the handset and press the intercom push button acoustic tones will be reproduced on the handset confirming the call is in progress or that the other unit is communicating...

Page 33: ...sh button at any moment with no dependence of the handset position Usual applications are the activation of stairs light second lock release First t T 740 Plus telephone must be configured with SW1 dip switch in PA output mode function see page 89 he T 740 Plus HZ HZ T 940 Plus Tekna Plus T 740 Plus PA To distributor door panel To stairs light push button The Tekna Plus monitor and the T 740 Plus ...

Page 34: ...ls until feedback fade out If feedback don t dissapears refer to the following hint O Continuous audio feedback w Check that A terminal is not shortcircuited with other terminals O Door open function no operates w Remember that this function is only available during call and communication progresses w w O The system cannot be programmed w Check that the switch number 2 of the SW2 configuration dip...

Page 35: ...102 NOTAS NOTES ...

Page 36: ...product meets the essentials requirements of applicable European Directives regarding Electrical Safety 2006 95 CEE Electromagnetic Compatibility 2004 108 ECC and as amended for CE Marking 93 68 ECC NOTA El funcionamiento de este equipo está sujeto a las siguientes condiciones 1 Este dispositivo no puede provocar interferencias dañinas y 2 debe aceptar cualquier interferencia recibida incluyendo l...

Reviews: