DOOR PANEL INSTALLATION
DOOR PANEL INSTALLATION
76
75
escription of the SW1 configuration dip-switch of
D
the EL500SE microprocessor module.
Placed to OFF if the EL500SE microprocessor module is configured as EL500
.
Set to ON if the EL500SE microprocessor module is configured as EL501
(only general door panel).
operating mode
operating mode
Selects the d
done from the
('AP'
terminal), see page 97.
Placed to ON: door opening timed at 3 seconds.
Set to OFF: door opening timed at 15 seconds.
oor opening time,
external push button
Selects the type of cable to be used for the video signal.
Placed to OFF: coaxial cable RG-59 o RG-11.
Set to ON: twisted pair.
Selects if the door panel has telecamera or not. In case of door panels without
telecamera (EL540 sound module) set to ON.
Plus system
, loads the installation with a communications resistor
Plus
. For a
proper system operation, placed to ON only in the closest door panel to the
backbone installation or in the general door panel (if exists), set the rest to
OFF.
Set to ON so that the volume tone emitted by the door panel:
(call reception, busy system and lock release) are
HIGH,
or placed to OFF if a
LOW
volume tone is desired.
Uno System
,
proper system operation, set to ON only in the closest door panel to the
backbone installation, placed the rest to OFF.
With digital repeater RD Plus/Uno:
In the backbone installation or after the inner door panel in systems with
general door panels, placed the door panel/s to OFF.
loads the installation with a communications resistor
Uno
. For a
6
6
7
6
7
6
Placed to ON,
porter's exchange (if exists).Set to OFF, the call is received in the apartment.
In general door panels systems with porter's exchange, this function is only
applicable to the general door panels not to the inner door panel/s.
the calls made on the door panel will be transferred to the
Factory default
6
7
8
6
7
8
The SW1 configuration dip-switch is located at the right side of
the circuit. It is accessed by opening the terminal connection
block protection cover.
inary coding of the SW2 configuration dip switch
B
of the EL500SE microprocessor module.
The switches set to OFF have null value. The values of the switches
set to ON are shown in the enclosed chart.
The backbone code will be calculated as the sum result of the
switches values set to ON.
Example: 64+0+16+0+4+2+1=87
Switch number:
ON value:
4
64
5
32
6
16
7
8
8
4
9
2
10
1
escription of the SW2 configuration dip-switch of
D
the EL500SE microprocessor module.
The SW2 configuration dip-switch is located in the center
of the circuit. It is accessed by opening the terminal
connection block protection cover.
Allows to activate the autoswitch-on function (audio-video communication
without previous call) at the door panel that has this switch to ON position.
In systems with several door panels activate this function only in one of
them; in systems with general door panel this function can be activated in
one door panel of each inner backbone (building).
Set to ON for monitor or telephones programming. Once the programming
progress is finished return the switch to OFF position. The programming
process is described on pages 84 (monitors), 87 and 91 (telephones).
Set to OFF in case of a master door panel. Each system must have only one
master door panel; the rest must be slaves (ON).
In systems with general door panel, set as master one door panel of each
inner backbone (building) and the general door panel as slave. Of this
way, the user will be able to distinguish since door panel are calling him.
Switches number 4 to 10 set the building code. In backbones with several
door panels, set the same code in all the panels; in systems with general
door panel, set different codes for each inner backbone (building). Set a
code between 1 and 120 for inner backbones (up to 127 with coded
panel) and a code 0 (
) for general door panel/s. To set the
code use binary coding as shown on the next paragraph.
Factory default
Factory default