background image

STARTING RECOMMENDATIONS

SYSTEM OPERATION

54

O

O
O

O

Install or modify the equipment 

without the power connected

.

O

The installation and handling of these equipments must be performed by 

authorised personnel

.

O

The entire installation must be at least 

40 cm

. away from any 

other installation

.

Do not use excessive force when tightening the screws of the power supply connector.
Before connecting the equipment, check the connections among the door pannel, telephones and the 

power connection. Do always follow the enclosed information.

When starting the equipment for the first time, or after a modification, the system will remain inactive for 

45 seconds because of the starting time. 

O
O

O
O

O
O
O
O
O

w
w
w

O

w

Audio door entry system with simplified installation (2-wire bus withouth polarity).
Up to 3 access door pannels being not necessary the use of switching units.

(Up to 2 access door pannels if there is a digital converter 

CD-2PLUS

 in the building or backbone).

Up to 120 telephones per instalation without using converters.
Up to 120 apartments with door pannels with push buttons and 120 apartments with coded panel (being 

necessary the use of digital converter 

CD-2PLUS)

.

Acoustic busy channel and call acknowledgement signals.
Maximum distance between the remote door pannel and furthest telephone: 100m.
Timed door opening for 3 seconds.
a.c. or d.c. lock release operated by relay.
In 

T-7720

 telephones:

Total private conversations.
Up to 1 additional telephone in every apartment.
Input for external door bell push button.

In 

T7722VD

 and 

T7822VD

 telephones have, besides the previous features:

Auxiliary push button with 2 possible functions:

e

Relay activation 

SAR-2PLUS.

e

Voltage-free contact (I máx: 40mA).

w

Up to 2 additional telephones in every apartment (only with 

T-7822VD

).

w

Call volume regulation with three positions: maximum, medium and disconnection.

w

Different call tones which identify the call procedure (main or secondary door panel or a call from the 

landing).

w

Call repeater

 S-45

 output.

O

It allows to install a porter´s exchange (being necessary the use of digital converter 

CD-2PLUS

).

O

To make a call, the visitor should press the push button corresponding to the apartment he/she wants to 

contact. Some acoustic tones will be heard confirming the call is in progress. At this moment the call is 
received in the dwelling. During the call the visitor can correct his/her call  by pressing the push button 
corresponding to the desired apartment, cancelling the original call.

O

In systems with several access doors, the other(s) door panel(s) will be automatically disconnected: if a 

visitor tries to call from a different door pannel, an acoustic tone will be heard to warn him/her that the 
system is engaged.

O

The call sounds over 45 seconds. If it is not answered in 45 seconds, then the channel will be disengaged. 

O

Pick up the telephone handset to establish communication.

O

The communication will last for one and a half minutes or until the handset is put down. Once the 

communication has finished the system will be disengaged.

O

In order to open the door, press the door release push button either while the call or the communication 

is in progress: the lock release is activated for 3 seconds pressing once the push button.

SYSTEM CHARACTERISTICS

INTRODUCTION

INDEX

53

First of all we would like to thank and congratulate you for the purchase of this product manufactured by 
Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 Certification 
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the 
legion of features this system offers. To obtain the maximum profit of these features and a properly wired 
installation, we kindly recommend you to expend a few minutes of your time to read this manual.

Introduction ...........................................53
Index.....................................................53
Safety precautions...................................53
Starting recommendations .......................54
System characteristics ..............................54
System operation ....................................54
Door panel ................................................

Description..........................................55
Embedding box positioning ...................56
Embedding box installation ..............56-57
Modules assembly ................................57
Electronic circuits assembly ....................58
Door panel fixation ...............................58
Placing the nameplate labels..................59
Push button wiring ...........................59-60
Push button coding ...............................61
EL520 configuration .............................62
Self-testing Leds ...................................62
Lamps wiring........................................63
Final adjustments & closing door panel....63

Power supply installation ..........................64

Lock release installation ...........................64
Telephones T-7720, T-7722VD & T-7822VD....

Description..........................................65
Function push button.............................65
JP3 jumper config. (only T-7822VD) ........66
Fixing the telephone ..............................66
Programming.......................................67

Optional connections..................................

Door bell push button............................68
External lock release activation...............68
Additional telephone or call repeater.......68
Lamps connection by means EL512 relay...69
Auxiliary devices activation ....................69
Garage door release ............................70

Wiring diagrams .........................................

With d.c lock release........................71-72
With a.c lock release / TF104............73-74
With a.c lock release / EL502 ............75-76

Troubleshooting hints ..............................77
Notes ....................................................78
Compliance...........................................79

O
O
O
O

w
w
w
w
w

O

w
w
w

O

Install or modify the equipment 

without the power connected

.

The installation and handling of these equipments must be performed by 

authorised personnel

.

The entire installation must be at least 

40 cm

. away from any 

other installation

.

With power supply:

w

Do not use excessive force when tightening the connector screws.
Install the power supply in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
Do not block ventilation holes of the unit so that air can circulate freely.
To avoid damage, the power supply has to be firmly fixed.
To avoid an electrical shock, neither remove the protection cover nor handle the connected wire in 

the terminals. 

With telephones, SAR-12/24 relay and S-45 call repeater:

Do not use excessive force when tightening the connector screws.
Install the power supply in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.

w

Do not block ventilation holes of the equipments so that air can circulate freely.

Do always follow the enclosed information.

SAFETY PRECAUTIONS

Summary of Contents for 2PLUS

Page 1: ...2PLUS Audio door entry system 2 wires without polarity installation manual T2PLUSML rev 0112 C d 50124627...

Page 2: ...ease activation 68 Additional telephone or call repeater 68 Lamps connection by means EL512 relay 69 Auxiliary devices activation 69 Garage door release 70 Wiring diagrams With d c lock release 71 72...

Page 3: ...T7822VD telephones have besides the previous features Auxiliary push button with 2 possible functions e Relay activation SAR 2PLUS e Voltage free contact I m x 40mA w Up to 2 additional telephones in...

Page 4: ...600 Closing heads 3xxx push buttons module CE 6xx embedding boxes EL520 Sound module in systems with more than eight push buttons Push buttons encoder EL516SE 55 N C 1 C 1 N A 1 N C 2 C 2 N A 2 in sy...

Page 5: ...mental conditions Nevertheless it is advisable to take additional precautions in order to extend its life such as visors covered places 1 CE610 125 140 56 Compact CE615 125 220 56 Modules Model W H D...

Page 6: ...g head marked ABAJO in the lower module and fix it by screwing the module shafts Place the module holder between the lower module and the next module but make sure that the holder notches are inside t...

Page 7: ...light push button and the microphone of the sound module with its own holes in the grille module Choose a direction to open the door panel this selection should facilitate the door panel wiring The op...

Page 8: ...ith sections between 0 1 and 0 25mm Twist the call wires as shown The call wires should be connected to the sound module El520 or to the corresponding push buttons encoder VERY IMPORTANT Link the push...

Page 9: ...Description CN2 conector 1 2 3 4 9 10 11 12 13 14 15 5 6 7 8 CN2 CN3 CP Black B Red P9 Green P10 Orange P11 Blue P12 Violet P13 Yellow P14 White P15 Brown Grey EL516SE Description CN3 conector P5 P6...

Page 10: ...6 P5 76 P7 106 2 2 32 62 92 17 47 77 107 3 3 33 63 93 18 48 78 108 4 4 34 64 94 19 49 79 109 5 5 35 65 95 20 50 80 110 6 6 36 66 96 21 51 81 111 7 7 37 67 97 22 52 82 112 8 8 EL516SE terminals EL520 t...

Page 11: ...the porter s exchange when it is activated Set the switch to OFF if this function is not required it needs a CD 2PLUS converter and that door panel capture is activated in the porter s exchange Set t...

Page 12: ...the door panel C If after starting the system it is considered that the audio volume is not appropriate do the necessary adjustments as it is shown 63 IMPORTANT Before closing the door panel s do a te...

Page 13: ...upply by means of the specified screws The power supply can be installed on a DIN 46277 guide by simply pressing it To disassemble the power supply use a plain screwdriver to lever it as it is shown o...

Page 14: ...the call reception or communication it allows the lock release activation erminal connection description T HZ BUS HZ Digital communication bus Connection to door bell BUS HZ 65 Detail of the T 7722VD...

Page 15: ...heating sources dusty locations or smoky environments The telephone can be fixed in a universal embedding box or directly on the wall For direct fixation on the wall drill two holes of using 6mm wall...

Page 16: ...the handset will emit a sound To programme the telephone as the main telephone replace the handset To programme it as slave telephone press the door release push button and then replace the handset 1...

Page 17: ...between the HZ telephone terminals The reproduced ringing tones vary depending on their provenance This allows the user to distinguish the origin of the call If during a conversation a call is made f...

Page 18: ...nes has two possible functions which are configurable by JP1 and JP2 jumpers BUS HZ PA S HZ PB S T 7722VD or T 7822VD JP1 JP2 Activate the SAR 2PLUS unit to switch on the ligths etc See document TSAR...

Page 19: ...230110 0 L2 BUS BUS HZ HZ S S HZ HZ S S T 7722VD T 7722VD PA PA PB PB BUS BUS HZ HZ S S HZ HZ S S T 7722VD T 7722VD PA PA PB PB JP1 JP2 JP1 JP2 JP1 JP2 JP1 JP2 FA PLUS C ver 938072 PRI SEC TF 104 Mai...

Page 20: ...panel IMPORTANT Do not insert the resistor with a 2Plus system BUS HZ HZ T 7720 BUS HZ HZ T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Linea BUS HZ S HZ S T...

Page 21: ...anel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second panel REMEMBER The maximum number of door panel in parallel without using converters is...

Page 22: ...LUS C ver 938072 PRI SEC TF 104 Main Next floor BUS BUS HZ HZ HZ HZ T 7720 T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Ligne BUS HZ S HZ S T 7722VD PA PB JP...

Page 23: ...take into account the connection towards others If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second pa...

Page 24: ...A PLUS C ver 938072 SEC PRI 230110 0 Slave door panel Next floor BUS BUS HZ HZ HZ HZ T 7720 T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Ligne IMPORTANT Do n...

Page 25: ...ke into account the connection towards others If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second pane...

Page 26: ...wn on page 63 In case of audio feedback reduce the volume until it disappears If audio feedback disappears only with the adjustments at minimum positions there could be another problem O Persistent au...

Page 27: ...NOTAS NOTES 78...

Page 28: ...uct meets the essentials requirements of applicable European Directives regarding Electrical Safety 2006 95 CEE Electromagnetic Compatibility 2004 108 ECC and as amended for CE Marking 93 68 ECC NOTA...

Reviews: