OPTIONAL CONNECTIONS

uxiliary devices connection.

A

REMEMBER:

 With the 

T-7720

 and 

T-7722VD 

telephones, the number of total elements in every 

apartment (telephones or call repeaters) can’t never surpass the two units.

   With the 

T-7822VD

 telephone, the number of total elements in every apartment (telephones or 

call repeaters) can’t never surpass the three units.

oor bell push button connection.

D

The 

T-7720, T-7722VD

 and 

T-7822VD

 telephones, incorporate 

as standards the call reception from the door bell push button. 
This feature spares the use of a bell, by placing a push button 
between the 'HZ' telephone terminals.

The  reproduced  ringing  tones  vary  depending  on  their 

provenance. This allows the user to distinguish the origin of the 
call. If during a conversation a call is made from the entrance 
door,  some  acoustic  tones  will  be  heard  as  a  warning  that 
someone else is calling.

BUS HZ HZ

T-7720, T7722VD

or T-7822VD

xternal lock release push buttons.

E

To activate the lock release by means of an external push button, place this 

push  button  between 

'CV1'

  and 

'CV2' 

terminals  of  the  door  panel, 

regardless of the kind of lock release.
It is a very useful function, you needn’t take a key when going out of the 
building.

CV1

CV2

EL 520

BUS HZ

PA

S+

HZ

PB

S-

T-7722VD or T-7822VD

BUS HZ HZ

BUS HZ HZ

S-45

S+ S-

T-7720, T-7722VD

or T-7822VD

T-7720, T-7722VD

or T-7822VD

TELEPHONES PROGRAMMING

rogramming the telephones.

P

Set to ON the configuration dip switch number 2 (as shown in page 

62). It is found at the rear of the sound module.

The door panel emits a sound announcing that it has come into the 

programming mode.

In systems with more than one door panel, proceed equally but only on 

the main door panel of each building.

67

IMPORTANT:

Installation with CD-2PLUS converter and coded panel or porter´s exchange, the call code linked to 

telephones will be from 1 up to 250.

2   Slave 

(only T-7822VD)

doble
click

Master

  Slave

st

nd

nd

Press the door release push button, and while pressing it, 

pick the handset up.

To show that the system is ready for programming, the door panel 

and  the  handset  will  emit  some  tones.  At  this  moment  it  is 
possible to establish audio communication. Release the door 
release push button.

Press the door panel push button that will call to 

this  telephone.  At  this  moment,  the  door 
panel and the handset will emit a sound.

To programme the telephone as the main telephone, replace the 

handset.

To programme it as slave telephone, press the door release push 

button and then replace the handset.

 1  

 

 

.

To program the 

T-7822VD

 as

Slave press the lock release push 

button once. After the door panel and handset reproduce a short 
tone, replace the handset If a long tone is reproduced then an 
error has occurred; reconfigure the telephone

To program the 

T-7822VD 

as

Slave press the lock release 

push 

twice.  After  the  door  panel  and  handset 

reproduce two short tones, replace the handset If a long tone 
is  reproduced  then  an  error  has  occurred;  reconfigure the 
telephone

 2     

button 

 

.

Every apartment must have one master unit only; in case of parallel units configure them as slave. 

With the 

T-7822VD

 is possible up to 2 additional telephones in every apartment.

Make a call to check the telephone has been successfully programmed. 

Proceed equally with the rest of telephones.

Once programming has been finished, set to OFF the programming switch. 

If you don’t, the door panel will emit a sound to advise that the system is 
still into the programming mode.

Summary of Contents for 2PLUS

Page 1: ...2PLUS Audio door entry system 2 wires without polarity installation manual T2PLUSML rev 0112 C d 50124627...

Page 2: ...ease activation 68 Additional telephone or call repeater 68 Lamps connection by means EL512 relay 69 Auxiliary devices activation 69 Garage door release 70 Wiring diagrams With d c lock release 71 72...

Page 3: ...T7822VD telephones have besides the previous features Auxiliary push button with 2 possible functions e Relay activation SAR 2PLUS e Voltage free contact I m x 40mA w Up to 2 additional telephones in...

Page 4: ...600 Closing heads 3xxx push buttons module CE 6xx embedding boxes EL520 Sound module in systems with more than eight push buttons Push buttons encoder EL516SE 55 N C 1 C 1 N A 1 N C 2 C 2 N A 2 in sy...

Page 5: ...mental conditions Nevertheless it is advisable to take additional precautions in order to extend its life such as visors covered places 1 CE610 125 140 56 Compact CE615 125 220 56 Modules Model W H D...

Page 6: ...g head marked ABAJO in the lower module and fix it by screwing the module shafts Place the module holder between the lower module and the next module but make sure that the holder notches are inside t...

Page 7: ...light push button and the microphone of the sound module with its own holes in the grille module Choose a direction to open the door panel this selection should facilitate the door panel wiring The op...

Page 8: ...ith sections between 0 1 and 0 25mm Twist the call wires as shown The call wires should be connected to the sound module El520 or to the corresponding push buttons encoder VERY IMPORTANT Link the push...

Page 9: ...Description CN2 conector 1 2 3 4 9 10 11 12 13 14 15 5 6 7 8 CN2 CN3 CP Black B Red P9 Green P10 Orange P11 Blue P12 Violet P13 Yellow P14 White P15 Brown Grey EL516SE Description CN3 conector P5 P6...

Page 10: ...6 P5 76 P7 106 2 2 32 62 92 17 47 77 107 3 3 33 63 93 18 48 78 108 4 4 34 64 94 19 49 79 109 5 5 35 65 95 20 50 80 110 6 6 36 66 96 21 51 81 111 7 7 37 67 97 22 52 82 112 8 8 EL516SE terminals EL520 t...

Page 11: ...the porter s exchange when it is activated Set the switch to OFF if this function is not required it needs a CD 2PLUS converter and that door panel capture is activated in the porter s exchange Set t...

Page 12: ...the door panel C If after starting the system it is considered that the audio volume is not appropriate do the necessary adjustments as it is shown 63 IMPORTANT Before closing the door panel s do a te...

Page 13: ...upply by means of the specified screws The power supply can be installed on a DIN 46277 guide by simply pressing it To disassemble the power supply use a plain screwdriver to lever it as it is shown o...

Page 14: ...the call reception or communication it allows the lock release activation erminal connection description T HZ BUS HZ Digital communication bus Connection to door bell BUS HZ 65 Detail of the T 7722VD...

Page 15: ...heating sources dusty locations or smoky environments The telephone can be fixed in a universal embedding box or directly on the wall For direct fixation on the wall drill two holes of using 6mm wall...

Page 16: ...the handset will emit a sound To programme the telephone as the main telephone replace the handset To programme it as slave telephone press the door release push button and then replace the handset 1...

Page 17: ...between the HZ telephone terminals The reproduced ringing tones vary depending on their provenance This allows the user to distinguish the origin of the call If during a conversation a call is made f...

Page 18: ...nes has two possible functions which are configurable by JP1 and JP2 jumpers BUS HZ PA S HZ PB S T 7722VD or T 7822VD JP1 JP2 Activate the SAR 2PLUS unit to switch on the ligths etc See document TSAR...

Page 19: ...230110 0 L2 BUS BUS HZ HZ S S HZ HZ S S T 7722VD T 7722VD PA PA PB PB BUS BUS HZ HZ S S HZ HZ S S T 7722VD T 7722VD PA PA PB PB JP1 JP2 JP1 JP2 JP1 JP2 JP1 JP2 FA PLUS C ver 938072 PRI SEC TF 104 Mai...

Page 20: ...panel IMPORTANT Do not insert the resistor with a 2Plus system BUS HZ HZ T 7720 BUS HZ HZ T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Linea BUS HZ S HZ S T...

Page 21: ...anel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second panel REMEMBER The maximum number of door panel in parallel without using converters is...

Page 22: ...LUS C ver 938072 PRI SEC TF 104 Main Next floor BUS BUS HZ HZ HZ HZ T 7720 T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Ligne BUS HZ S HZ S T 7722VD PA PB JP...

Page 23: ...take into account the connection towards others If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second pa...

Page 24: ...A PLUS C ver 938072 SEC PRI 230110 0 Slave door panel Next floor BUS BUS HZ HZ HZ HZ T 7720 T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Ligne IMPORTANT Do n...

Page 25: ...ke into account the connection towards others If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second pane...

Page 26: ...wn on page 63 In case of audio feedback reduce the volume until it disappears If audio feedback disappears only with the adjustments at minimum positions there could be another problem O Persistent au...

Page 27: ...NOTAS NOTES 78...

Page 28: ...uct meets the essentials requirements of applicable European Directives regarding Electrical Safety 2006 95 CEE Electromagnetic Compatibility 2004 108 ECC and as amended for CE Marking 93 68 ECC NOTA...

Reviews: