DOOR PANEL INSTALLATION

mbedding box positioning.

E

1650

1850

1450

Make a hole on the wall in order to place the upper part of the door panel at 1,65m height.
     The hole dimensions will depend on the number of door panel modules.

The door panel has been designed to stand diverse environmental conditions. Nevertheless,
     it is advisable to take additional precautions in order to extend its life (such as visors, 
     covered places ...). 

1

CE610

125
140

56

Compact

CE615

125
220

56

Modules 

Model

W

H
D

2

CE620

125
257

56

3

CE630

125 mm.
374 mm.
  56 mm.

reparing the cables entry.

P

     Break the bottom flange 

to pass the cables through it

. If the door panel

     has more than one embedding box, break the side flanges to 
     wire the modules and join the embedding boxes by means of the 
     UC junctions.

56

DOOR PANEL DESCRIPTION

oor panel description.

D

2xxx

grille module

600 

 Closing heads

3xxx

push buttons module

CE-6xx embedding boxes

EL520

Sound module

, in systems with more than eight push buttons.

Push buttons 

encoder

EL516SE

55

NC1

+

-

C1

NA1

NC2

C2

NA2

, in systems with more than three push buttons 
  modules.

Relay unit

EL512

Summary of Contents for 2PLUS

Page 1: ...2PLUS Audio door entry system 2 wires without polarity installation manual T2PLUSML rev 0112 C d 50124627...

Page 2: ...ease activation 68 Additional telephone or call repeater 68 Lamps connection by means EL512 relay 69 Auxiliary devices activation 69 Garage door release 70 Wiring diagrams With d c lock release 71 72...

Page 3: ...T7822VD telephones have besides the previous features Auxiliary push button with 2 possible functions e Relay activation SAR 2PLUS e Voltage free contact I m x 40mA w Up to 2 additional telephones in...

Page 4: ...600 Closing heads 3xxx push buttons module CE 6xx embedding boxes EL520 Sound module in systems with more than eight push buttons Push buttons encoder EL516SE 55 N C 1 C 1 N A 1 N C 2 C 2 N A 2 in sy...

Page 5: ...mental conditions Nevertheless it is advisable to take additional precautions in order to extend its life such as visors covered places 1 CE610 125 140 56 Compact CE615 125 220 56 Modules Model W H D...

Page 6: ...g head marked ABAJO in the lower module and fix it by screwing the module shafts Place the module holder between the lower module and the next module but make sure that the holder notches are inside t...

Page 7: ...light push button and the microphone of the sound module with its own holes in the grille module Choose a direction to open the door panel this selection should facilitate the door panel wiring The op...

Page 8: ...ith sections between 0 1 and 0 25mm Twist the call wires as shown The call wires should be connected to the sound module El520 or to the corresponding push buttons encoder VERY IMPORTANT Link the push...

Page 9: ...Description CN2 conector 1 2 3 4 9 10 11 12 13 14 15 5 6 7 8 CN2 CN3 CP Black B Red P9 Green P10 Orange P11 Blue P12 Violet P13 Yellow P14 White P15 Brown Grey EL516SE Description CN3 conector P5 P6...

Page 10: ...6 P5 76 P7 106 2 2 32 62 92 17 47 77 107 3 3 33 63 93 18 48 78 108 4 4 34 64 94 19 49 79 109 5 5 35 65 95 20 50 80 110 6 6 36 66 96 21 51 81 111 7 7 37 67 97 22 52 82 112 8 8 EL516SE terminals EL520 t...

Page 11: ...the porter s exchange when it is activated Set the switch to OFF if this function is not required it needs a CD 2PLUS converter and that door panel capture is activated in the porter s exchange Set t...

Page 12: ...the door panel C If after starting the system it is considered that the audio volume is not appropriate do the necessary adjustments as it is shown 63 IMPORTANT Before closing the door panel s do a te...

Page 13: ...upply by means of the specified screws The power supply can be installed on a DIN 46277 guide by simply pressing it To disassemble the power supply use a plain screwdriver to lever it as it is shown o...

Page 14: ...the call reception or communication it allows the lock release activation erminal connection description T HZ BUS HZ Digital communication bus Connection to door bell BUS HZ 65 Detail of the T 7722VD...

Page 15: ...heating sources dusty locations or smoky environments The telephone can be fixed in a universal embedding box or directly on the wall For direct fixation on the wall drill two holes of using 6mm wall...

Page 16: ...the handset will emit a sound To programme the telephone as the main telephone replace the handset To programme it as slave telephone press the door release push button and then replace the handset 1...

Page 17: ...between the HZ telephone terminals The reproduced ringing tones vary depending on their provenance This allows the user to distinguish the origin of the call If during a conversation a call is made f...

Page 18: ...nes has two possible functions which are configurable by JP1 and JP2 jumpers BUS HZ PA S HZ PB S T 7722VD or T 7822VD JP1 JP2 Activate the SAR 2PLUS unit to switch on the ligths etc See document TSAR...

Page 19: ...230110 0 L2 BUS BUS HZ HZ S S HZ HZ S S T 7722VD T 7722VD PA PA PB PB BUS BUS HZ HZ S S HZ HZ S S T 7722VD T 7722VD PA PA PB PB JP1 JP2 JP1 JP2 JP1 JP2 JP1 JP2 FA PLUS C ver 938072 PRI SEC TF 104 Mai...

Page 20: ...panel IMPORTANT Do not insert the resistor with a 2Plus system BUS HZ HZ T 7720 BUS HZ HZ T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Linea BUS HZ S HZ S T...

Page 21: ...anel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second panel REMEMBER The maximum number of door panel in parallel without using converters is...

Page 22: ...LUS C ver 938072 PRI SEC TF 104 Main Next floor BUS BUS HZ HZ HZ HZ T 7720 T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Ligne BUS HZ S HZ S T 7722VD PA PB JP...

Page 23: ...take into account the connection towards others If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second pa...

Page 24: ...A PLUS C ver 938072 SEC PRI 230110 0 Slave door panel Next floor BUS BUS HZ HZ HZ HZ T 7720 T 7720 BUS HZ HZ T 7720 BUS HZ S HZ S T 7722VD PA PB BUS HZ S HZ S T 7822VD PA PB BUS F Ligne IMPORTANT Do n...

Page 25: ...ke into account the connection towards others If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels wire them as the second pane...

Page 26: ...wn on page 63 In case of audio feedback reduce the volume until it disappears If audio feedback disappears only with the adjustments at minimum positions there could be another problem O Persistent au...

Page 27: ...NOTAS NOTES 78...

Page 28: ...uct meets the essentials requirements of applicable European Directives regarding Electrical Safety 2006 95 CEE Electromagnetic Compatibility 2004 108 ECC and as amended for CE Marking 93 68 ECC NOTA...

Reviews: