Technical Assistance

For help in installing, operating, or troubleshooting this control, you may call for technical
assistance at 800-921-7665.  Goldline Controls technicians are available from 8:00AM to 8:00PM
Eastern Time, Monday through Friday.  You may call at other times and leave a message, and a
technician will call you back as soon as possible.

Temperature/Resistance/Voltage

All Goldline controls use 10K thermistor sensors.  When disconnected from the control the sensor
will read 10K ohms at 25ºC/77ºF.  Refer to the chart below for the resistance at other temperatures.
For a given temperature, the resistance reading should be accurate to ±1%.  For a given resistance
reading, the temperature reading should be accurate to ±0.5ºF.  Voltage measurements should be
accurate to ± 2%.   Ohm measurements made with sensor disconnected from unit.  Voltage
measurements made with sensor connected to unit and power applied.  Sensor voltages are DC volts.

1 1

°F

Ohms

Volts

°F

Ohms

Volts

°F

Ohms

Volts

°F

Ohms

Volts

1

82,719

   

4.46

41

25,391

   

3.59

81

9,076

     

2.38

121

3,679

     

1.34

2

80,142

   

4.45

42

24,704

   

3.56

82

8,861

     

2.35

122

3,602

     

1.32

3

77,656

   

4.43

43

24,037

   

3.53

83

8,651

     

2.32

123

3,527

     

1.30

4

75,255

   

4.41

44

23,391

   

3.50

84

8,447

     

2.29

124

3,454

     

1.28

5

72,937

   

4.40

45

22,764

   

3.47

85

8,249

     

2.26

125

3,382

     

1.26

6

70,698

   

4.38

46

22,156

   

3.45

86

8,056

     

2.23

126

3,312

     

1.24

7

68,535

   

4.36

47

21,566

   

3.42

87

7,867

     

2.20

127

3,244

     

1.22

8

66,447

   

4.35

48

20,993

   

3.39

88

7,684

     

2.17

128

3,177

     

1.21

9

64,428

   

4.33

49

20,438

   

3.36

89

7,506

     

2.14

129

3,112

     

1.19

10

62,479

   

4.31

50

19,900

   

3.33

90

7,333

     

2.12

130

3,049

     

1.17

11

60,595

   

4.29

51

19,377

   

3.30

91

7,164

     

2.09

131

2,987

     

1.15

12

58,774

   

4.27

52

18,870

   

3.27

92

6,999

     

2.06

132

2,926

     

1.13

13

57,014

   

4.25

53

18,377

   

3.24

93

6,839

     

2.03

133

2,867

     

1.11

14

55,313

   

4.23

54

17,899

   

3.21

94

6,683

     

2.00

134

2,809

     

1.10

15

53,669

   

4.21

55

17,435

   

3.18

95

6,530

     

1.98

135

2,752

     

1.08

16

52,078

   

4.19

56

16,985

   

3.15

96

6,382

     

1.95

136

2,697

     

1.06

17

50,541

   

4.17

57

16,548

   

3.12

97

6,238

     

1.92

137

2,643

     

1.05

18

49,054

   

4.15

58

16,123

   

3.09

98

6,097

     

1.89

138

2,591

     

1.03

19

47,616

   

4.13

59

15,711

   

3.06

99

5,960

     

1.87

139

2,539

     

1.01

20

46,225

   

4.11

60

15,310

   

3.02

100

5,827

     

1.84

140

2,489

     

1.00

21

44,879

   

4.09

61

14,921

   

2.99

101

5,697

     

1.81

141

2,440

     

0.98

22

43,577

   

4.07

62

14,543

   

2.96

102

5,570

     

1.79

142

2,392

     

0.97

23

42,318

   

4.04

63

14,176

   

2.93

103

5,446

     

1.76

143

2,345

     

0.95

24

41,099

   

4.02

64

13,820

   

2.90

104

5,326

     

1.74

144

2,299

     

0.93

25

39,919

   

4.00

65

13,473

   

2.87

105

5,208

     

1.71

145

2,254

     

0.92

26

38,777

   

3.97

66

13,136

   

2.84

106

5,094

     

1.69

146

2,210

     

0.90

27

37,671

   

3.95

67

12,809

   

2.81

107

4,982

     

1.66

147

2,167

     

0.89

28

36,601

   

3.93

68

12,491

   

2.78

108

4,873

     

1.64

148

2,125

     

0.88

29

35,565

   

3.90

69

12,182

   

2.75

109

4,767

     

1.61

149

2,084

     

0.86

30

34,561

   

3.88

70

11,882

   

2.72

110

4,664

     

1.59

150

2,044

     

0.85

31

33,590

   

3.85

71

11,589

   

2.68

111

4,563

     

1.57

151

2,005

     

0.84

32

32,648

   

3.83

72

11,305

   

2.65

112

4,464

     

1.54

152

1,966

     

0.82

33

31,737

   

3.80

73

11,029

   

2.62

113

4,368

     

1.52

153

1,929

     

0.81

34

30,853

   

3.78

74

10,761

   

2.59

114

4,274

     

1.50

154

1,892

     

0.80

35

29,998

   

3.75

75

10,500

   

2.56

115

4,183

     

1.47

155

1,856

     

0.78

36

29,169

   

3.72

76

10,246

   

2.53

116

4,094

     

1.45

156

1,821

     

0.77

37

28,365

   

3.70

77

9,999

     

2.50

117

4,007

     

1.43

157

1,787

     

0.76

38

27,587

   

3.67

78

9,758

     

2.47

118

3,922

     

1.41

158

1,753

     

0.75

39

26,832

   

3.64

79

9,525

     

2.44

119

3,839

     

1.39

159

1,720

     

0.73

40

26,100

   

3.61

80

9,297

     

2.41

120

3,758

     

1.37

160

1,688

     

0.72

Summary of Contents for GL-235-LV

Page 1: ...3NF of the pool tem perature or the pool temperature is lowered below the set desired temperature SINGLE SETTING FOR DESIRED TEMPERATURE The GL 235 logic is set by a single dial adjustment with the d...

Page 2: ...eplacement SEE WARRANTY STATEMENT FOR COMPLETE DETAILS Service You Can Count On Visit www goldlinecontrols com or call 800 343 0826 to speak with a qualified technical support representative Our techn...

Page 3: ...GL 235 Solar Pool Controller Installation OperationManual for models GL 235 LV GL 235 LV HV www goldlinecontrols com 888 921 7665 North Kingstown RI USA LDLINE CONTROLS INC G...

Page 4: ...s spas and hot tubs These models provide differential temperature control with an adjustable calibrated water temperature high limit Automatic nocturnal cooling for pools that overheat in hot climates...

Page 5: ...ery important if recirculate freeze protection or nocturnal cooling functions are being used Also this function can be used on systems where the system should operate whenever solar heat is available...

Page 6: ...protection starts early enough to protect the system The GL 235 is shipped from the factory with recirculate freeze protection disabled the jumper is present but installed on one pin only To activate...

Page 7: ...n the MANUAL OFF position during cold weather Also note that the switch does NOT turn power off to the GL 235 Troubleshooting No Power Indicator Check main power circuit breakers Check fuse Fuse Repla...

Page 8: ...SENSOR indicator blinking If the CHECK SENSOR indicator is blinking there may be a possible open circuit or short circuit with the solar sensor Using a voltmeter measure the voltage across the termina...

Page 9: ...BasicInstallationofGL 235 LV Figure2 7...

Page 10: ...GL 235 LV HVwithHighVoltageOutputusedforTimerOverride Figure3 8...

Page 11: ...GL 235 LV HVwithHighVoltageOutputusedforBoosterPump Figure4 9...

Page 12: ...10 Measuring Voltage of Pool Sensor Use the same method to measure the Solar Sensor Figure5...

Page 13: ...29 51 19 377 3 30 91 7 164 2 09 131 2 987 1 15 12 58 774 4 27 52 18 870 3 27 92 6 999 2 06 132 2 926 1 13 13 57 014 4 25 53 18 377 3 24 93 6 839 2 03 133 2 867 1 11 14 55 313 4 23 54 17 899 3 21 94 6...

Page 14: ...warrants its solar control products installed outside of the USA or Canada to be free from defects in material or workmanship under normal use and service for one year from date of the initial system...

Reviews: