Solar Pool Heating Control

M  

Automatically Maximizes Solar System

Heat Collection

M  

Precise Calibrated Temperature Setting Dial

M  

Single Model Handles all Systems-Old or New

Pools, Spas, 12 or 24VAC Actuators.

M  

Automatic Switch Over from Solar Heating to

Nocturnal Cooling if Desired

M  

Standard 120/240 VAC 50/60 Hz. Input 

& 12 and 24 VAC Output

M  

Goldline’s Proven Reliability and Performance

M  

Industry’s Only 5-year Limited Warranty*

M  

Goldline Combo (GLC)

is GL-235 LV or GL-235 LV-HV

Control, Diverter Valve, Actuator & Sensors

Unique 5 Year Warranty*

*Refer to Limited Warranty Statement for Details.

Corporate Office:
42 Ladd Street
East Greenwich, RI 02818
(401) 884-6990
(401) 885-1500 Fax

Western Regional Office:
7171 Alvarado Road, Suite 104
La Mesa, CA 91942
(619) 462-4298
(619) 462-4498 Fax

Description

The GL-235 is designed to meet the need for easy installation,
dependable operation, and serviceability. The GL-235 incorpo-
rates unique,  microprocesser based construction to ensure relia-
bility and accurate performance. The GL-235 offers advanced
operating features to provide differential temperature control,
selectable high limit, programmable recirculation freeze protec-
tion, nocturnal cooling and optional booster pump control.

AUTOMATIC HEATING: 

If the collectors are warmer than the

pool water by 4

N

or more, and the pool is below the selected

desired temperature, the valve will rotate allowing heat collection.

This heat collection will stop when the solar sensor falls to within

1.5

N

F of the pool temperature or the pool temperature exeeds the

“desired temperature” set on dial.

AUTOMATIC COOLING: 

(Field selectable option) If the col-

lectors are cooler than the pool water by 6

N

F or more, and the

pool is above the selected desired temperature, the valve will

rotate allowing cooling via the solar collectors. The heat dissipa-

tion will stop when the collectors rise within 3

N

F of the pool tem-

perature or the pool temperature is lowered below the set desired

temperature.

SINGLE SETTING FOR DESIRED TEMPERATURE:

The

GL-235 logic is set by a single dial adjustment with the desired

pool/spa temperatures clearly indicated. The dial is calibrated

with the temperatures from 70

N

F to a high of 104

N

F for quick and

easy, user-friendly operation. The temperature set indicates set

pool/spa temperature, and the GL-235 will automatically dete

r-

mine if the water should be solar heated or cooled, thus maxi-

mizing the system capabilities.

TERMINAL STRIP CONNECTIONS: 

For input power, and

sensor inputs. Controls also have industry standard 3 pin connec-
tors for both forward and reverse valve actuator operation and
screw terminal connectors.

LED INDICATORS: 

Show the status of the system operation,

Four highly visible LED’s show 1) power to the control, 2) power
output directing valves and/or pump to collect heat (heating), 3)
power output directing valves and/or pump to dissipate heat
(cooling), 4) sensor fault indicator shows sensor(s) not operating
properly.

GL-235 VALVE OUPUT: 

Rating is the industry standard 24

VAC. A jumper switches the output to 12VAC for compatibility
with older valve actuators. Output is fuse protected.

RECIRCULATION FREEZE PROTECTION: 

(field selectable

operation) turns the GL-235 output ON, directing warmer

pool/spa water through the collectors when near freezing tempera-

tures are reached at the collector sensor. The GL-235 will allow

recirculation when the collector temperature rises to 42

N

F. Two

10K Ohm sensors are required for operation. One or more freeze

snap switches are recommended if freeze recirculation protection

is utilized. 

Important--see installation instructions before using

Recirculation Freeze.

SYSTEM TEST SWITCH: 

Allows the user to manually over-

ride the automatic function of the GL-235 and verify operation.

A

Am

me

er

riic

ca

as

 

#

#11  B

Be

es

st

t  S

Se

elllliin

ng

g  S

So

olla

ar

r  C

Co

on

nt

tr

ro

olllle

er

r

A

Am

me

er

riic

ca

as

s  #

#11  B

Be

es

st

t  S

Se

elllliin

ng

g  S

So

olla

ar

r  C

Co

on

nt

tr

ro

olllle

er

r

Summary of Contents for GL-235-LV

Page 1: ...3NF of the pool tem perature or the pool temperature is lowered below the set desired temperature SINGLE SETTING FOR DESIRED TEMPERATURE The GL 235 logic is set by a single dial adjustment with the d...

Page 2: ...eplacement SEE WARRANTY STATEMENT FOR COMPLETE DETAILS Service You Can Count On Visit www goldlinecontrols com or call 800 343 0826 to speak with a qualified technical support representative Our techn...

Page 3: ...GL 235 Solar Pool Controller Installation OperationManual for models GL 235 LV GL 235 LV HV www goldlinecontrols com 888 921 7665 North Kingstown RI USA LDLINE CONTROLS INC G...

Page 4: ...s spas and hot tubs These models provide differential temperature control with an adjustable calibrated water temperature high limit Automatic nocturnal cooling for pools that overheat in hot climates...

Page 5: ...ery important if recirculate freeze protection or nocturnal cooling functions are being used Also this function can be used on systems where the system should operate whenever solar heat is available...

Page 6: ...protection starts early enough to protect the system The GL 235 is shipped from the factory with recirculate freeze protection disabled the jumper is present but installed on one pin only To activate...

Page 7: ...n the MANUAL OFF position during cold weather Also note that the switch does NOT turn power off to the GL 235 Troubleshooting No Power Indicator Check main power circuit breakers Check fuse Fuse Repla...

Page 8: ...SENSOR indicator blinking If the CHECK SENSOR indicator is blinking there may be a possible open circuit or short circuit with the solar sensor Using a voltmeter measure the voltage across the termina...

Page 9: ...BasicInstallationofGL 235 LV Figure2 7...

Page 10: ...GL 235 LV HVwithHighVoltageOutputusedforTimerOverride Figure3 8...

Page 11: ...GL 235 LV HVwithHighVoltageOutputusedforBoosterPump Figure4 9...

Page 12: ...10 Measuring Voltage of Pool Sensor Use the same method to measure the Solar Sensor Figure5...

Page 13: ...29 51 19 377 3 30 91 7 164 2 09 131 2 987 1 15 12 58 774 4 27 52 18 870 3 27 92 6 999 2 06 132 2 926 1 13 13 57 014 4 25 53 18 377 3 24 93 6 839 2 03 133 2 867 1 11 14 55 313 4 23 54 17 899 3 21 94 6...

Page 14: ...warrants its solar control products installed outside of the USA or Canada to be free from defects in material or workmanship under normal use and service for one year from date of the initial system...

Reviews: