Solar Pool Heating Control
Corporate Office:
42 Ladd Street
East Greenwich, RI 02818
(401) 884-6990
(401) 884-1500 Fax
Western Regional Office:
7171 Alvarado Road, Suite 104
La Mesa, CA 91942
(619) 462-4298
(619) 462-4498 Fax
Model GL-235-LV-HV
The model GL-235-LV-HV has two outputs: 1) Selectable low volt-
age output for 12/24 VAC valve actuator. Wire via 3 pin connectors
or terminal block (compatible with older actuators). 2) Isolated con-
tact, high voltage output for 120/240 VAC booster pump or time
clock override. Order sensors and freeze snap switches separately.
Model GL-235-LV
The GL-235-LV is similar to the GL-235-LV-HV, but has a low volt-
age output only.
Temperature Sensors
All Goldline temperature sensors are 10K Thermistors which are
accirate to +/-
2N
F. The sensors are double-dip potted in silicone for
maximum protection from moisture.
PC:
Multi-purpose sensor that can be used for both Solar (surface
mount) or Pool/Water (drill-in plastic piping).
SC-1/4:
Brass screw-in sensor with
3
” NPT pipe thread. Screws
directly into drain plug on the pump strainer basket.
Freeze Snap Switches
Goldline recommends the use of one or more freeze snap switches to
be wired in series with the solar sensor if the recirculate freeze pro-
tection feature is being used. Both snap switch models operate identi-
cally, however, the GC-1 is designed to meet the highest aerospace &
military specifications.
GC-1:
Opens at 44
N
+/- 4
N
F, closes at 54
N
+/- 5
N
F (premium)
GC-2:
Opens at 44
N
+/- 4
N
F, closes at 54
N
+/- 5
N
F (standard)
5 Year Limited Warranty*
Goldline Controls offers a 5 year limited warranty on all soalr con-
trols and accesories. This warranty covers the repair or replacement
of the control at no cost for the first 36 months. For years 4 and 5,
Goldline will charge a fee of up to 60% of the current list plus ship-
ping charges for repair or replacement.
*SEE WARRANTY STATEMENT FOR COMPLETE DETAILS.
Service You Can Count On
Visit www.goldlinecontrols.com, or call (800) 343-0826 to speak
with a qualified technical support representative. Our technichians
can assist you in selecting the correct controls and sensors for your
system and help troubleshoot any problems after installation.
Goldline Combo (GLC)
The “GLC” package contains everything required to automatically
control most solar pool heating systems. The “GLC” provides the
industry’s #1 best selling control, valve, actuator, and sensors togeth-
er in one box. The “GLC” makes inventory control easier, ensures all
parts arrive at the job site, and components remain protected in facto-
ry-fresh condition. The Goldline “GLC” consists of the GL-235-LV
or GL-235-LV-HV control, a 24 VAC actuator, a valve (see chart)
and 2 sensors (see chart). For GLC with the GL-235-LV-HV control
add HV after GLC in Model number.
MODEL
GLC-1P-A
GLC-1P-B
GLC-2P-A
GLC-2P-B
GLC-2NP-A
GLC-2NP-B
VALVE
1.5”/2” positive seal valve
1.5”/2” positive seal valve
2”/2.5” positive seal valve
2”/2.5” positive seal valve
2”/2.5” non-positive seal valve
2”/2.5” non-positive seal valve
SENSORS
2 PC sensors
1 PC sensor, 1 SC-
3
sensor
2 PC sensors
1 PC sensor, 1 SC-
3
sensor
2 PC sensors
1 PC sensor, 1 SC-
3
sensor
(HV-add HV after the GLC to make combo with GL-235-LV-HV)
Specifications
Power:
105-130VAC, .5A 50/60Hz.
or
192-250VAC, .3A 50/60Hz.
Output:
Low Voltage
12/24VAC,20VA,1.7/.85A
3 pin connectors for both
forward and reverse operation
Model GL-235-LV-HV also has
terminal block connections
GL-235-LV-HV only:
SPST-NO isolated contact
115VAC, 1 HP
240VAC, 2 HP
Sensors:
2 required-thermistor, 10K @
25
N
C/77
N
F. (snap switches
recommended if recirculate
freeze protection is used)
On differential:
4
N
F
Off differential:
1.5
N
F
High Limit:
70-104
N
F selectable via
calibrated scale
Recirculate freeze:
on at 40
N
F, off at 42
N
F
Nocturnal cooling:
On when collector 6
N
F less than
pool
and
pool hotter than high
limit, off when collector 3
N
F
less than pool
or
pool cooler
than high limit