a)
Rotation Reduction Gears
Lube Point(s) –Replaceable Filter.
Capacity –As required.
Lube - 7408B-1 Gear Grease.
1/*,RU/LWKLXP6RDS&9LVFRVLW\#&RUHTXLYDOHQW
Interval –Every 3 months or 150 hours.
Comment –Apply grease and rotate in 90 degree intervals until bearing is completely lubricated.
Do not over-lubricate the bearings, otherwise it will cause damage to outside seal of casing.
b)
Hydraulic tank
)DFWRU\ILOO&KHYURQ$:
Liquid Level –50-62 L (13.2-16.4 us gal ).
Interval –Check level daily;Change every year or 2,000 hours of operation.
Comment –On new machines, those recently overhauled, or after changing hydraulic oil, operate all
system a minimum of two complete cycles and recheck oil level in reservoir.
$-(%RRP/LIW2SHUDWRU¶V0DQXDO
3DJH