c) Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the
platform must not touch or operate the machine until energized power lines are shut off.
Do not operate the machine during lightning or storms.
Do not use the machine as a ground for welding.
Tip-over hazard
Occupants, equipment and materials shall not exceed the maximum platform capacity.
Table 1-2 Rated load
Maximum platform capacity
Unrestricted range of motion
250 kg /550 lb
Maximum occupants
2
a)
Do not exceed the maximum platform capacity;
b)
Do not attach a platform rated at 250 kg /550 lb to machines with any other rated load. See the
serial label for the maximum rated capacity;
c)
The weight in options and accessories (such as pipe, panel bracket and welder) will reduce rated
platform capacity and must be factored into total platform load.See the decals with the options and
accessories;
d)
If using accessories, read, understand and obey the decals and instructions with the accessory;
e)
Do not raise or extend the boom unless the machine is on a firm, level surface.
Do not depend on the tilt alarm as a level indicator. The tilt alarm sounds in the platform only when the
$-(%RRP/LIW2SHUDWRU¶V0DQXDO