Global Mainstream Dynamic Energy Technology Ltd.
- 29 -
User Manual
Powervortex 5200TL hybrid inverter
4.1.5.6 Setting Maximum Discharging Current
Figure 26 discharging current setting
Id refers to the maximum discharging current with setting range from 5A to 80A. The default
value is 60A. Please set this current value according to the battery recommended value of
different battery types. Press “OK” to finish this setting and you will enter the setting interface as
shown in Figure .
4.1.5.7 Setting Battery Maximum Charging Current
Figure 27 maximum charging current setting
Ic refers to the maximum charging current with setting range from 5A to 80A. The default value is
60A. Please set this current value according to the battery recommended value of different
battery types. Press “OK” to finish this setting and you will enter the setting interface as shown in