Flying multiple KNV Lines in a horizontal row
See Figure 27. To fly a row of KNV Line fixtures from a rigging truss:
Mount the first two KNV Lines on the truss as described in ‘Flying a single KNV Line
from a rigging truss’ on page 37, fastening them end-to-end using KNV Module
Connectors with reference to Figure 26.
If there is any risk that a fixture will cause injury or damage if it falls, secure it with an
approved safety cable as described in ‘Securing with a safety cable’ on page 19
as soon as you have fastened it to the truss.
Continue adding KNV Line fixtures one at a time in the same way. You can add an
unlimited number of fixtures side-by-side, but each KNV Line must be either:
•
suspended independently of the other KNV Lines with its own rigging clamp, or
•
fastened with KNV Module Connectors on both sides to KNV Lines that are
suspended independently with their own rigging clamps.
Do not use a KNV Module Connector to bear the weight of a KNV Line that is
hanging freely at any other angle than vertically downwards.
Support the weight of every KNV Line that you install until it is either suspended from
its own rigging clamp or supported on both sides.
Figure 27. KNV Line fixtures flown from rigging truss