NOTE:  This product must be installed by a certified electrician in 

accordance with local codes.
Traces of smoke or odor when unit is initiated indicates that small 

amounts of oil leaked on heating coil during manufacturing. It will 

evaporate quickly and should not re-occur. Make sure the appliance 

location is well ventilated during operation. It is normal for the unit 

to emit sounds when turned on for the first time.
When using electrical appliances, please follow these basic 

precautions to reduce risk of fire, electrical shock, injury or 

property damage:

1.  Read all instructions prior to using heater.
2.  Heater will be hot when in use. Prevent bare skin from touching hot surface 

to avoid injury. Keep combustible materials such as but not limited to 
furniture, bedding or clothing at least 3 feet (0.9 m) away from heater.

3.  Extreme caution and supervision is necessary when heater is used 

near children or pets and when the heater is left operating while 

unattended.

4.  Always switch off heater when not in use.
5.  Do not operate heater if unit malfunctions, has been dropped, or is damaged 

in any way. Disconnect power at service panel and have heater inspected 
by a reputable electrician before reusing.

6.  Do not use outdoors. 
7.  To disconnect heater, turn off power circuit at main disconnect panel.
8.  For wall or ceiling installation, do not install less than 8 feet (2.4 m) high 

from floor and closer than 1 foot (0.3 m) to any adjacent vertical surfaces 
or walls. Keep at least 4.5 inches (11.5 cm) from back wall (with or without 
wall hanging mounting bracket).

9.  Do not insert or allow foreign objects to enter any ventilation or exhaust 

opening as this may cause electric shock, fire or damage to heater.

10.  To prevent a possible fire, do not block air intakes or exhaust in 

any manner.

11.  Units contain hot and arcing internal equipment. To reduce the risk of fire, 

do not use in areas where gasoline, paint, or flammable vapors and liquids 
are used or stored.

12.  Use this heater only as described in this manual. Any other use not 

recommended by the manufacturer may cause fire, electric shock  
or injury.

13.  This heater is not intended for use in bathrooms, laundry areas and similar 

indoor locations. Never position heater near water. 

Model 653577

globalindustrial.ca

Distribucion Industrial Globales S DE RL DE CF

Assembly Instructions

Instrucciones de Ensamblaje

Directives d’assemblage

Customer Service

US: 1-800-645-2986

Servicio de atención al Cliente

México: 01.800.681.6940

Service à la clientèle

Canada: 888-645-2986

WARNING

Please read all instructions before using this heater.

E360195

SAVE FOR FUTURE REFERENCE

Summary of Contents for 653577

Page 1: ...ctrician before reusing 6 Do not use outdoors 7 To disconnect heater turn off power circuit at main disconnect panel 8 For wall or ceiling installation do not install less than 8 feet 2 4 m high from...

Page 2: ...Diagram Main Switch 1 Phase 208 240 VAC 60Hz WARNING All wiring must be installed by a certified electrician in accordance with electrical safety standards CAUTION Keep electrical cords drapery furnis...

Page 3: ...in flexible conduit and connect to the wiring compartment via the round hole at back of the unit 11 Connect the power supply wires 10 AWG to the pigtail leads of the unit in the wiring compartment Use...

Page 4: ...e sure not to wet heating element or switches Allow unit to dry completely before restarting MAINTENANCE AND CLEANING CAUTION Do not allow water to run into the interior of the heater as this could ca...

Page 5: ...lizarlo 6 No apto para exteriores 7 Para desconectar el calentador apague el circuito de poder en el panel de desconexi n principal 8 Para instalaciones en paredes o techos no instale el calentador a...

Page 6: ...de Cableado Interruptor Principal 1 Fase 208 240 VAC 60Hz Todo el cableado debe ser instalado por un electricista certificado siguiendo los est ndares de seguridad el ctrica PRECAUCI N Mantenga los c...

Page 7: ...d 11 Conecte los cables Fuente de poder 10 AWG a los conductores flexibles de la unidad en el compartimiento de cableado Utilice tenazas engarzadoras para hacer las conexiones a los cables conductores...

Page 8: ...o interruptores Permita que la unidad se seque completamente antes de reiniciarla MANTENIMIENTO Y LIMPIEZA No permita que entre agua al interior del calentador ya que esto podr a causar un incendio un...

Page 9: ...chauffage par un lectricien reconnu avant de le r utiliser 6 N utilisez pas l appareil l ext rieur 7 Pour d brancher l appareil de chauffage coupez le circuit d alimentation au panneau principal 8 Pou...

Page 10: ...ALARM 0 1 2 3 OFF A Bo tier sup rieur B Bouton de r glage de l inclinaison C Grille avant de l chappement D Grille d a ration E Panneau de contr le F Indicateur d alimentation G Voyant DEL d attentio...

Page 11: ...de l unit 11 Branchez les fils de l alimentation lectrique 10 AWG aux fils de la queue de cochon dans le compartiment du c blage de l unit Utilisez des pinces sertir pour brancher aux fils corresponda...

Page 12: ...ment chauffant ou les interrupteurs Laissez s cher l unit avant de le red marrer MAINTENANCE ENTRETIEN ET NETTOYAGE MISE EN GARDE Ne laissez pas d eau couler l int rieur de l appareil de chauffage ce...