Error Code
CDU Error Code Description and Diagnostics
1. Check note path for jam.
2. Check note for interference or blockage.
3. Check belt for proper engagement.
4. Replace CDU.
C005B
2nd cassette failure to pick up
1. Check note inside cassette for interference by foreign object.
2. Check gears inside cassette for debris between gear teeth.
3. Check rollers inside cassette for damage.
4. Check push plate for interference.
5. Check cassette exit path for blockage.
6. Replace cassette.
C006A
Note from 2nd CST not arriving at double timing sensor (H)
1. Check sensor (H) for blockage.
2. Check to ensure sensor is working properly.
3. Check cable from sensor to main B/D for damage or loose connector.
4. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
5. Replace Inlet sensor when the voltage is not in the normal range.
6. Replace Main B/D.
C007B
Sensor blocked during initialize
1. Measure sensor voltage <transmitter normal range of 1~3V>.
normal range of 50~250 mV at empty
normal range of 2~5 V when blocked
2. Replace sensor when the voltage is not in the normal range.
3. Replace Main B/D.
C0080
2nd cassette exit sensor (J) blocked after dispensing
1. Check sensors RIGHT/LEFT for blockage.
2. Check to ensure sensor is working properly.
3. Check cable from sensor to main B/D for damage or loose connector.
4. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
5. Replace Inlet sensor when the voltage is not in the normal range.
6. Replace main B/D.
C0081
Double detection timing sensor (H) blocked during dispensing
1. Check sensor for blockage.
2. Check cable from DBL sensor to main B/D for damage or loose connector.
3. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
4. Replace sensor when the voltage is not in the normal range.
5. Replace main B/D.
C0082
Note from cassette not arriving at double timing sensor (H)