       WARNING

Risk Of Electrical Shock

•   Turn off power prior to performing any maintenance.

•   Verify supply voltage accuracy.

•   Ensure  all  electrical  and  grounded  connections  are

in accordance  with  the  National  Electrical  Code  and

any other applicable local code requirements.

•   All  wiring  connections  should  be  capped  with

approved wire connectors.

The  warnings,  precautions,  and  instructions 

discussed cannot cover all possible conditions and 

situations that may occur. Failure to heed these warnings 

may result in property damage and personal injury.

General Safety Information

•   To  reduce  the  risk  of  property  damage,  personal

injury, electric  shock,  falling  equipment,  and  other

hazards please read all instructions and warnings.

•   Installation, service, and maintenance should be

•   All  parties  must  follow  proper  safety  procedures

and precautions at all times.

•  Do Not Install Damaged Products!

9

Wall Mounted Water Bottle 

Refilling Station

14

16

15

       CAUTION 

Make sure all wires are 

tucked in before attaching 

cover plate to lower cover. 

Connect reset cable to activation button
•   Connect the Reset Button connection cable to 

the Activation Buttons located at the top of the 

filter access door frame.

•   Reinstall the filter access door using the provided key.
•   Unit is now ready for use.

Reset button connection

Reattach lower cover 

•   Reattach the Lower Cover to the Cooling System 

using (4) H1 anti-theft screws.

•   Fasten  the  Lower  Cover  to  the  bottom  of  the 

Stainless Steel Pan using (2) H1 anti-theft screws.

•   Remove the filter access door using 

the provided key.

H5

H1

H1

10

b82045fc-0b136962-90871f19-f891407c

2

Summary of Contents for 761219

Page 1: ...hnician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of water damage Ensure proper ventilation by allowing appropriate clearance of hou...

Page 2: ...ep these instructions in a safe location for future reference Keep compressor in upright position for 24 hours before water connections and initial power on Failure to do so will void warranty It is r...

Page 3: ...3 User s Manual Wall Mounted Water Bottle Refilling Station Check local codes for plumbing requirements prior to installation b82045fc 0b136962 90871f19 f891407c 287mm 10 1 4 in...

Page 4: ...cess Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw Star Key remove the 4 screws at the bottom of...

Page 5: ...right side up and carefully feed connections though the Stainless Steel Pan hole Ensure gasket is seated properly and lies flat Attach Bottle Filler Top Assembly to the Stainless Steel Pan using 2 H3...

Page 6: ...s Connect white Activation Connector C to Power Supply C in the Cooling System Attach stainless steel pan Feed the Reset Button Connection through the Cooling System s frame and carefully lower the St...

Page 7: ...e wall using appropriate anchors Hanging assembled unit to wall Carefully hang assembled bottle filler onto the wall by lowering onto both top and bottom wall mount brackets 8 9 Note To comply with AD...

Page 8: ...d into place Turnbothwatercontrolvalvestotheopenposition Check all connections for leaks If leaks are detected ensure all connections are tight and are fully inserted 11 13 12 Closed Closed Closed Ope...

Page 9: ...ards please read all instructions and warnings Installation service and maintenance should be All parties must follow proper safety procedures and precautions at all times Do Not Install Damaged Produ...

Page 10: ...ial water flow may have sputter due to air in the water lines this will be eliminated once air is purged from all water lines To operate bottle filler verify proper dispensing by placing bottle hand o...

Page 11: ...elect 3600 4 Tap ENTER button to confirm your filter size Resetting Bottle Counter 1 Press and hold ENTER button for 5 seconds 2 Tap ENTER button until Reset Ct is displayed on the LCD screen then tap...

Page 12: ...When filter level is at 0 0 LED bars will be displayed LCD will display CHG FLT entire time Issue Possible Cause Suggested Action Water temperature not cool The thermostat is set too high Lower the w...

Reviews: