![Global Industrial 761219 User Manual Download Page 10](http://html1.mh-extra.com/html/global-industrial/761219/761219_user-manual_2233021010.webp)
Wall Mounted Water Bottle
Refilling Station
10
User's Manual
Adjusting Settings
Water Flow Pressure: Adjust the water flow pressure as
needed by turning the water control valve. Turn clockwise
to decrease the water pressure, or counterclockwise to
increase the water pressure.
Note: Initial dispenses may have air in line which may
cause a sputter. Allow a few seconds for air to be purged
from the water line.
Water Temperature: Machine comes with a preset water
temperature of around 45°F. If a different temperature is
required, remove Lower Cover and access the thermostat
on the front housing frame. Using a flathead screwdriver, turn
thermostat screw clockwise to lower temperature setting.
Note: Please allow 5-10 minutes for water temperature
to change.
Operation
Note: Initial water flow may have sputter due to air in the
water lines; this will be eliminated once air is purged from
all water lines.
To operate bottle filler, verify proper dispensing by
placing bottle, hand or any opaque object in front of the
sensor area.
When unit is plugged in for the first time, the LCD will
display: 00000000. If not, the filter monitor needs to be
reset – refer to Resetting Filter Monitor
section below.
Installing/Replacing Filter
1. Remove filter access door on the lower cover using the
provided key (H5).
2.Grasp old filter and turn counterclockwise to remove
from the filter head.
3. Press and hold ENTER button for 5 seconds to reset
this bottle counter number to zero 00000000.
4. Tap SET button 1 time or wait 5 seconds to return to
standard bottle counter view.
Replacement Filters: Model 670336
For more information visit: globalindustrial.com or
call 1-800-645-2982.
H6
Clockwise
To Install
Counterclockwise
b82045fc-0b136962-90871f19-f891407c