background image

User's Manual

Wall Mounted Water Bottle 

Refilling Station

2

Risk of Electrical Shock

•   Disconnect power before servicing unit.

•   Electric supply must be identical in voltage, cycle and 

phase  to  those  specified  in  the  specifications  below. 

Unit must be plugged into a GFCI outlet.

•   Always pull the plug – not the cord – when disconnecting 

from the outlet.

•   DO  NOT  use  if  the  power  cord  is  worn  or  damaged. 

Power  cords  should  only  be  replaced  by  qualified 

service technicians using genuine replacement parts.

•  Check local codes for electrical requirements.

•  DO NOT disassemble or modify unit.
•  Use Global Industrial filters only – Model 670336

Note:

•   Prior to installation, consult with local, state, and federal 

codes for proper mounting height.

•   All installation and service should  only be performed by 

authorized personnel.

•   Dimensions  shown  below  comply  with  ADA  requirements 

at time of printing.

•   Allow 4" minimum clearance on both sides to allow for 

proper ventilation through cabinet louvers.

•   Thoroughly flush all water lines and fittings of all foreign 

matter  before  connecting  to  the  Cooling  System. 

Failure to do so will void warranty.

Required Tools:

1.  Safety Glasses

2.  Safety Gloves

3.  Electric Drill

4.  Phillips Head Screwdriver

5.  Flathead Screwdriver

6.  Tape Measure

7.  Pencil

8.  Level Device

9.  (11) 75-lb. Capacity Flat Head Wall Anchors

 

(appropriate for your wall type)

10.  (11) Flat Head Anchor Screws

        WARNING

•   Review manual thoroughly and verify rough-ins before 

installation.  Keep  these  instructions  in  a  safe  location 

for future reference.

•   Keep  compressor  in  upright  position  for  24  hours 

before water connections and initial power-on. 

Failure 

to do so will void warranty.

•   It  is  recommended  to  assemble  this  product  on  a 

tabletop or bench.

•   Fixture  must  be  mounted  to  a  flat  finished  industry 

standard  wall  surface.  The  wall  surface  must  have 

adequate  support  to  secure  the  fixture,  with  the 

addition of wall anchors (not included) if required.

•   All  receptacles  must  be  wired  to  a  GFCI  protected 

circuit.  Fixture  must  be  earth  grounded  per  National 

Electric Code (NEC).

•   Inspect fixture and all parts for damage.

Package Contents:

Box 1 - 761319 Top Assembly for Bottle Filler

Box 2 - 761212 Cooling System for Water Fountain

Stainless 

Steel Pan

Water 

Filter

Not Pictured:

Hardware Bag

Mounting Stencil

Mounting Bracket

(attached to rear)

Cooling System

Rubber Gasket

Mounting Bracket 

(attached to rear)

Bottle Filler

Top Assembly

Note: This product complies with ADA when installed 

according to the requirements outlined in this manual.  

Installation may require additional accessories to be fully 

compliant.  If needed, consult with the local Authority 

Having Jurisdiction (AHJ).

Voltage/Hertz

115V/60Hz

*Chilling Capacity

5.3 GPH

Full-Load Amps

1.9 Amps

Rated Watts

185 W

Filter Capacity

4750 or 3600 Gallons

Quick-Fill Rate

1.0 GPM

Water Flow

Laminar

Certification

UL399 and CAN/CSA 22.2 No. 120 ADA
Compliant

Overall Dimensions

18

1/8

"W x 16"D x 37

13/16

"H

System 761219 Certified by IAPMO R

&

T against 

NSF/ANSI/CAN372 for lead free compliance

Filter 670336 certified by NSF to NSF/ANSI 42

&

53

* At 46° - 54° (F) against ambient air temperature of 77° (F)

Summary of Contents for 761219

Page 1: ...hnician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of water damage Ensure proper ventilation by allowing appropriate clearance of hou...

Page 2: ...ep these instructions in a safe location for future reference Keep compressor in upright position for 24 hours before water connections and initial power on Failure to do so will void warranty It is r...

Page 3: ...3 User s Manual Wall Mounted Water Bottle Refilling Station Check local codes for plumbing requirements prior to installation b82045fc 0b136962 90871f19 f891407c 287mm 10 1 4 in...

Page 4: ...cess Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw Star Key remove the 4 screws at the bottom of...

Page 5: ...right side up and carefully feed connections though the Stainless Steel Pan hole Ensure gasket is seated properly and lies flat Attach Bottle Filler Top Assembly to the Stainless Steel Pan using 2 H3...

Page 6: ...s Connect white Activation Connector C to Power Supply C in the Cooling System Attach stainless steel pan Feed the Reset Button Connection through the Cooling System s frame and carefully lower the St...

Page 7: ...e wall using appropriate anchors Hanging assembled unit to wall Carefully hang assembled bottle filler onto the wall by lowering onto both top and bottom wall mount brackets 8 9 Note To comply with AD...

Page 8: ...d into place Turnbothwatercontrolvalvestotheopenposition Check all connections for leaks If leaks are detected ensure all connections are tight and are fully inserted 11 13 12 Closed Closed Closed Ope...

Page 9: ...ards please read all instructions and warnings Installation service and maintenance should be All parties must follow proper safety procedures and precautions at all times Do Not Install Damaged Produ...

Page 10: ...ial water flow may have sputter due to air in the water lines this will be eliminated once air is purged from all water lines To operate bottle filler verify proper dispensing by placing bottle hand o...

Page 11: ...elect 3600 4 Tap ENTER button to confirm your filter size Resetting Bottle Counter 1 Press and hold ENTER button for 5 seconds 2 Tap ENTER button until Reset Ct is displayed on the LCD screen then tap...

Page 12: ...When filter level is at 0 0 LED bars will be displayed LCD will display CHG FLT entire time Issue Possible Cause Suggested Action Water temperature not cool The thermostat is set too high Lower the w...

Reviews: