Assembly Instructions

Wall Mounted Water Bottle 

Refilling Station

Connect Water Lines

•   Connect  the  water  line  (#2)  in  the  Bottle  Filler 

Top Assembly to the Water Control Valve (#2) 

in the Cooling System.

•   Push line until locked into place.

Connect Wire Connectors

•   Connect white Activation Connector (C) to 

Power Supply (C) in the Cooling System.

Attach stainless steel pan

•   Feed the Reset Button Connection through 

the Cooling System's frame and carefully 

lower the Stainless Steel Pan on top of the 

Cooling System.

•   Attach the Stainless Steel Pan to the 

Cooling System using (2) H4 screws.

       CAUTION 

Avoid crossing wires 

against sharp edges

7A

7C

7B

H4

Reset Button 

Connection

Reset Button 

Connection

b82045fc-0b136962-90871f19-f891407c

Summary of Contents for 761219

Page 1: ...hnician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of water damage Ensure proper ventilation by allowing appropriate clearance of hou...

Page 2: ...ep these instructions in a safe location for future reference Keep compressor in upright position for 24 hours before water connections and initial power on Failure to do so will void warranty It is r...

Page 3: ...3 User s Manual Wall Mounted Water Bottle Refilling Station Check local codes for plumbing requirements prior to installation b82045fc 0b136962 90871f19 f891407c 287mm 10 1 4 in...

Page 4: ...cess Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw Star Key remove the 4 screws at the bottom of...

Page 5: ...right side up and carefully feed connections though the Stainless Steel Pan hole Ensure gasket is seated properly and lies flat Attach Bottle Filler Top Assembly to the Stainless Steel Pan using 2 H3...

Page 6: ...s Connect white Activation Connector C to Power Supply C in the Cooling System Attach stainless steel pan Feed the Reset Button Connection through the Cooling System s frame and carefully lower the St...

Page 7: ...e wall using appropriate anchors Hanging assembled unit to wall Carefully hang assembled bottle filler onto the wall by lowering onto both top and bottom wall mount brackets 8 9 Note To comply with AD...

Page 8: ...d into place Turnbothwatercontrolvalvestotheopenposition Check all connections for leaks If leaks are detected ensure all connections are tight and are fully inserted 11 13 12 Closed Closed Closed Ope...

Page 9: ...ards please read all instructions and warnings Installation service and maintenance should be All parties must follow proper safety procedures and precautions at all times Do Not Install Damaged Produ...

Page 10: ...ial water flow may have sputter due to air in the water lines this will be eliminated once air is purged from all water lines To operate bottle filler verify proper dispensing by placing bottle hand o...

Page 11: ...elect 3600 4 Tap ENTER button to confirm your filter size Resetting Bottle Counter 1 Press and hold ENTER button for 5 seconds 2 Tap ENTER button until Reset Ct is displayed on the LCD screen then tap...

Page 12: ...When filter level is at 0 0 LED bars will be displayed LCD will display CHG FLT entire time Issue Possible Cause Suggested Action Water temperature not cool The thermostat is set too high Lower the w...

Reviews: