5.
Then set the BOTTOM limit, by pressing [CLOSE] button, and confirm BOTTOM limit position by pressing
[STOP] button. 2 beeps will signal for successful programming.
**While setting the TOP limit the [SEL/ADJ] light will turn
red
and starts blink.
6.
Once limits are set, the door will automatically perform a full calibration cycle.
5.0 Force Setting
1.
Press and hold [S], release finger when [F] lights in red
2.
Press [S] again, when the light of [SEL/ADJ] turns RED, ORANGE, or GREEN:
GREEN
indicates the lightest force
ORANGE
indicates the medium force
RED
indicates the heaviest force
3.
2 beeps will signal for successful setting and the unit will automatically exit the setup.
6.0 Automatic Closing Setting
1.
Press and hold [S], and release finger when the red light turns from [F] to [A]
2.
Press [S] again, when the light of [SEL/ADJ] turns RED, ORANGE, GREEN or OFF.
GREEN
indicates auto closing time at 10 seconds
ORANGE
indicates auto closing time at 20 seconds
RED
indicates auto closing time at 30 seconds
Light
OFF
indicates there is no auto closing function.
3.
2 beeps will signal for successful setting and the unit will automatically exit the setup.
Please note the Auto-close time delay will only start once the door is fully opened.
If for some reason the door has to be left opened for longer period, press the stop button before the door