CHAPTER 5: CONFIGURATION
Motor:
S3-1
S3-2
S3-3
S3-4
2 Pole
ON
ON
ON
ON
4 Pole
ON
ON
ON
OFF
6 Pole
ON
ON
OFF
ON
8 Pole
ON
ON
OFF
OFF
10 Pole
ON
OFF
ON
ON
12 Pole
ON
OFF
ON
OFF
Zero
ON
OFF
OFF
ON
Index
ON
OFF
OFF
OFF
5.4.4 Motor Pole Configuration:
Dip-switch S3-1, S3-2, S3-3 and S3-4 configures the pre-amp for the number of poles in
the motor. They are also used to set up certain calibration modes. Refer to the chart below
and set the dip switches for the correct number of poles.
5.5 Two/Three Phase Input Current Mode Amplifier Configuration:
The following table shows the dip switches that need to be configured for the Type A, B,
C, and D configurations. The standard configuration is shown in bold.
Type A
Type B
Type C
Type D
INHIBIT
S1-5 - OFF
S1-3 - ON
S1-5 - ON
S1-3 - OFF
S1-5 - OFF
S1-3 - OFF
S1-5 - ON
S1-3 - ON
RESET IN
S1-4 - OFF
S1-2 - OFF
S1-4 - ON
S1-2 - ON
S1-4 - OFF
S1-2 - ON
S1-4 - ON
S1-2 - OFF
MTR TEMP
S1-1 - OFF
not available
S1-1 - ON
not available
5.5.1 +15V/+5V Logic Level Configuration:
•
+15V: S1-6 - OFF.
•
+5V: S1-6 - ON.
5.5.2 Standard Configuration for Two/Three Phase Input Current Mode:
Dip-switch
Switch Name
2Ø current mode 3Ø current mode
S1-8
2 pase input
ON
OFF
S1-7
3 phase input
OFF
ON