CHAPTER 1: DESCRIPTION, FEATURES AND SPECIFICATIONS
•
Fused regen circuit (shunt regulator) with a 50W internal load resistor bank bleeds off
excess DC Buss voltage when decelerating a large load inertia. Additional regen resistor
can be connected externally.
1.3 Specifications:
This section contains the specifications for the brushless trapezoidal, sine/resolver and
two or three phase input current mode D.C. Servo Amplifiers. These specifications also
include power supplies for the amplifiers.
NOTE: All data in this section is based on the following ambient conditions: 120
o
F (50
o
C)
maximum. Forced air cooling.
1.3.1 Single Amplifier Module (SMA8X05-1):
The amplifier module(s) require an external DC power supply which must include a
bridge rectifier, buss capacitor, solid-state relay and shunt regulator. Forced air cooling is
required to meet the maximum power ratings specified below.
1.3.1.1
Input and Output Power
:
Input Power/
Buss Voltage(B+)
Output Power
(current)
Standard
High Power
R.M.S.
Peak
R.M.S.
Peak
60VAC/80VDC
5A
10A
10A
20A
120VAC/170VDC
3A
6A
6A
12A
240VAC/340VDC
2A
6A
4A
12A
Amplifier
Model
Signal Input
Maximum
Voltage
(VDC)
Minimum
Impedance
+
Velocity Gain
Amp./Volt
Current Gain
Amp./Volt
8105/8205
Differential
)
13
10,000
15,000(min.)
0-5
8105/8205
Single-ended
)
13
10,000
15,000(min.)
0-5
8305
2/3phase input
)
13
10,000
0-5
1.3.1.2 Signal Inputs
:
1.3.1.3
Digital Inputs
:
•
)
Limit, Inhibit & Reset:
40/-0.5V max. Terminated by 10,000
+
.
•
Fault (as input):
40/-0.5V max. Terminated by 10,000
+
.
•
Typical for all digital inputs: Digital inputs have hysteresis with thresholds at 1/3 and
2/3 of +5V or +15V depending on range select jumper.