Page 38
PLATINUM SYSTEM READY
SYSTEM DESIGN
Fitting Template
A first fix fitting template is supplied with the
unit to allow for the first fix pipework to be
installed prior to the connection of the unit.
1
1
2
2
3
3
4
4
5
5
6
6
A
A
B
B
C
C
D
D
REV No
REVISION
DATE
APPROVED
This drawing is the property of
Gledhill Building Products Ltd
and may not, without the express
written consent of the company, be
copied in whole or in part, or used
for any purpose other than that for
which it is supplied.
Gledhill Building Products Ltd
Sycamore Estate
Blackpool
FY4 3RL
Tel No: 01253 474550
Fax No: 01253 474551
Status
Material Specification
Original Scale:
All Dimensions In Millimetres
Do Not Scale
If In Doubt-Ask
Drawn
Checked
Eng. Approval
Mfg. Approval
Date
Date
Date
Date
Project
Title
Drawing No
Sheet No.
For Review
AndrewT
14/09/2017
StainlessLite Pro
PP Floor Template
MIP-926
1 /1
Drawing No
MIP-926-P1
Rev No.
P1
Sh1 /1
A3
Tol/- 3.0mm
1 : 4
1
2
3
4
5a
6
7
8
9
10
Cylinder
Hot Outlet
Wiring Centre
Immersion /
Control Stat
5
P
re
lim
in
ar
y
Co
py
Number
Description
Size (mm)
1
CH Zone
1
22
2
CH Zone
2
22
3
Flow From Boiler
28
4
Return To Boiler
28
5
CH Return (120/150)
22
5a
CH Return (180 up)
22
6
Tundish Outlet
22
7
Secondary Circulation
22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
700
Minimum Cupboard Width =
0
282
487
528
579
616
673
700
0
282
342
392
442
543
566
627
700
0
10
1
16
0
23
2
28
5
34
7
36
9
48
7
53
0
67
0
70
0
329
P1
Alternate CH Position Added
14/09/2017
1
1
2
2
3
3
4
4
5
5
6
6
A
A
B
B
C
C
D
D
REV No
REVISION
DATE
APPROVED
This drawing is the property of
Gledhill Building Products Ltd
and may not, without the express
written consent of the company, be
copied in whole or in part, or used
for any purpose other than that for
which it is supplied.
Gledhill Building Products Ltd
Sycamore Estate
Blackpool
FY4 3RL
Tel No: 01253 474550
Fax No: 01253 474551
Status
Material Specification
Original Scale:
All Dimensions In Millimetres
Do Not Scale
If In Doubt-Ask
Drawn
Checked
Eng. Approval
Mfg. Approval
Date
Date
Date
Date
Project
Title
Drawing No
Sheet No.
For Review
AndrewT
14/09/2017
StainlessLite Pro
PP Floor Template
MIP-926
1 /1
Drawing No
MIP-926-P1
Rev No.
P1
Sh1 /1
A3
Tol/- 3.0mm
1 : 4
1
2
3
4
5a
6
7
8
9
10
Cylinder
Hot Outlet
Wiring Centre
Immersion /
Control Stat
5
P
re
lim
in
ar
y
Co
py
Number
Description
Size (mm)
1
CH Zone
1
22
2
CH Zone
2
22
3
Flow From Boiler
28
4
Return To Boiler
28
5
CH Return (120/150)
22
5a
CH Return (180 up)
22
6
Tundish Outlet
22
7
Secondary Circulation
22
8
Balanced Cold Feed
22/28
9
Mains Cold Supply
22/28
10
Hot Water Feed
22/28
All pipe holes are optional.
All pipe hole sizes are dictated by the
property / design. Therefore are a general indication.
The template is a general guide for installation
rather than a rule that must be followed without
deviation.
700
Minimum Cupboard Width =
0
282
487
528
579
616
673
700
0
282
342
392
442
543
566
627
700
0
10
1
16
0
23
2
28
5
34
7
36
9
48
7
53
0
67
0
70
0
329
P1
Alternate CH Position Added
14/09/2017
Summary of Contents for PLATINUM D120
Page 45: ...Page 45 NOTES ...
Page 46: ...Page 46 NOTES ...