7.1—Leak detection system
The Crea7ionEVO PLUS has two leak detection sensors which are located on the combustion fire line safety box and
system safety box.
Thus, if there is some kind of leak or fuel/ liquid spill on top of Crea7ionEVO PLUS, the system turns off, visualizing
immediately the error message "Ethanol Leaking" on the display:
1. " Leakage"
The system will emit one uninterrupted beep until you delete the error by clicking on the
"OFF"
button on the display.
In this situation, even you insist on the connection, the system does not start lighting, returning again the "Ethanol
Leaking" error.
To resolve this error, please contact a qualified technician.
7.2—Vibration Sensor
The Crea7ionEVO PLUS is equipped with a vibration sensor which it was designed to ensure user safety when an acci-
dental shock occurs. It activates itself, turning OFF the Crea7ionEVO PLUS, when the device suffers an external shock
during operation.
If it happens, the following information will appear on the display:
1.
”Error Incl/Vib”
To remove this error, please click on the OFF button (
"O"
) on the display.
You can only remove this error when the external vibration ends.
7.3—Tank door locking system
The system does not allow the filling of bioethanol in the tank if it is not at the proper temperature. To do it, you must
wait about 5-10 minutes until the system has cooled naturally and unlock the door of the tank zone, after it having
been in operation.
The system can not be used if the tank door is not closed.
Likewise, the tank can not be filled if the system is not cooled.
The system emits one beep and appears the information that it is possible to open the door on the display:
1.
"Door Unlocked"
Forcing the door, the system can be damaged, appearing after the error message "Damaged Door" on the display:
2.
"Doorlock Error"