USER MANUAL
DIGITAL READOUT VISION 518
MT02_A31_B_VI518_GIVI_ENG rev. A
Pag. 30/32
ADDITIONAL INFORMATION
Model
VISION VI518
1 display - 1 input
Display
8 high-efficiency digits h = 13 mm
Incremental encoder input
signals
2 square waves with phase displacement of 90° ± 5°
and zero reference
5 Vdc or 12 Vdc (TERMINAL BOARD) 250 mA
MAX
Maximum input frequency
250 kHz
MAX
Absolute (SSI) encoder input
signals
RS-422 – Clock, Clock , Data, Data
Power supply
230 Vac
±
10% - 50/60 Hz
110 Vac
±
10% - 60 Hz
24 Vac
±
10% - 50/60 Hz
Current consumption
40 mA
MAX
(230
Vac)
80 mA
MAX
(110
Vac)
350 mA
MAX
(24
Vac)
Memory
permanent for configuration and user settings
(last data operating memory)
Linear resolution
200 - 100 - 50 - 20 - 10 - 5 - 2 - 1 - 0.5 µm
0.01 - 0.005 - 0.002 - 0.001 - 0.0005 - 0.0002 - 0.0001 -
0.00005 - 0.00002 inch
Angular resolution
1 - 0.5 - 0.2 - 0.1 - 0.05 - 0.02 - 0.01 - 0.005 - 0.002 - 0.001 °
Operating temperature
0 °C
÷
50 °C
Storage temperature
-20 °C
÷
70 °C
Weight
450 g
Options
UR2 RELAY
OUTPUTS
-S
SERIAL OUTPUT RS-232
SSI
ABSOLUTE (SSI) ENCODER INPUT
ABSOLUTE (SSI) ENCODER PARAMETERS
Clock frequency
125 / 250 / 500 kHz
Number of position bits
8-32 bit
Output code
Binary, Gray
Optional bits
Parity bit, Error bit
Without prior notice, the products may be subject to modifications that the Manufacturer reserves to
introduce as deemed necessary for their improvement.
TECHNICAL CHARACTERISTICS