Axis in linear reading:
NO =
a timed intervention is generated when the position passes from a value
lower than the intervention position, to a higher or equal value.
NC =
a timed intervention is generated when the position passes from a value
higher or equal to the intervention position, to a lower value.
Axis in angular reading:
NO =
a timed intervention is generated when the position enters the circular
sector set, on the basis of the rotation direction.
NC =
a timed intervention is generated when the position exits the circular
sector set, on the basis of the rotation direction.
To disable the timed output and return to the standard relay output, it is sufficient to set a
timing duration of
0 seconds
on the concerned relay.
Axis in linear reading:
Let us suppose that, in their rest condition, relay 1 has been set with the NC (normally
closed) status and relay 2 has been set with NO (normally open) status.
To program the following intervention positions, proceed as indicated below:
RELAY R1
INTERVENTION POSITION 150.00
RELAY R2
INTERVENTION POSITION 300.00
Press
4 2
r E L E 1
To set the position 150.00 for relay 1,
Press
enter the desired intervention position
for relay 1
X
X
X
X
X
.
X
X
Use
and
to enter it and press EXE
0
0
0
1
5
0
.
0
To set the intervention position for relay 2,
press
4 2
3 0 0 . 0 0
Note.
The
key is used to select the desired relay (2 in our example).
SETTING INTERVENTION POSITIONS