USER MANUAL
DIGITAL READOUT VISION 518
MT02_A31_B_VI518_GIVI_ENG rev. A
Pag. 29/32
With function F 98771 it is possible to modify the setting of the communication parameters
of the absolute SSI encoder.
The parameters that could be set are the following:
STEP SSI PARAMETER
RANGE
DEFAULT
01
Baud Rate
125 / 250 / 500 kHz
250 kHz
02
Number of Bits
8 - 32
24
03
Output Code
Binary / Gray
Binary
04
Parity Bit
No / Even / Odd
No
05
Error Bit
No / 0=bit low in case of error /
1=bit high in case of error
No
To recall a function that cannot be selected with the +/- key,
Press
to enter the function selection
F - F n
Press
F 0 0 0 0
Use
and
to enter the number of the
desired function and press EXE
F 9 8 7 7 1
Press
to select the Baud Rate and press EXE
0 1 - 2 5 0
Use
and
to set the Number of Bits and
press EXE
0 2 - 4
Press
to select the Output Code and
press EXE
0 3 - b i n
Press
to select the Parity Bit and
press EXE
0 4 - b P n
Press
to select the Error Bit
0 5 - b E n
Press
to confirm the selection.
All the data are permanently stored in the memory and the instrument quits the function.
To cancel the modifications made and quit the function, press CLR before the last setting.
SETTING SSI PARAMETERS
F 98771