![Giorik Steambox Evolution SEHE Series Installation, Operation And Maintenace Manual Download Page 13](http://html1.mh-extra.com/html/giorik/steambox-evolution-sehe-series/steambox-evolution-sehe-series_installation-operation-and-maintenace-manual_2228800013.webp)
13
power supply plug will be connected, to position 0 (zero)� Have the socket
cable section checked by qualified staff to make sure it suits the power
absorbed by the device�
Loosen the screws that fix the
left side of the oven and remove it
(
Fig. 10
). The flexible cable must
be in polychloroprene or equivalent
oil-resistant synthetic elastomer
sub-sheath� Use a cable with section
suitable to the load corresponding to
every appliance, as indicated in the
table (
tab. 1
)�
Insert the power cord into the hole of the cable gland located on
the left bottom side of the oven�
Connect the cable to the terminal block following the instructions
given in
tab. 2
�
Secure the cable with the cable gland�
The supply voltage of the appliance is operation must not
deviate from the nominal voltage by ± 10%�
The appliance must be included into an equipotential system whose efficiency
is checked in compliance with the standards in force� For the connection use
the clamp, placed on the frame and marked with the symbol
Fig. 11
, to
which a cable with the minimum section of 10 mm² must be connected�
For gas ovens, wait until the gas connection to the appliance has also been
completed before re-mounting the side panel of the oven; instead, for electric
ovens, on finishing the electric connection, re-mount the side panel.
Gas Model
SEHG061 SETG061 SEHG062 SETG062 SEHG101 SETG101 SEHG102 SETG102 SEHG201 SETG201 SEHG202 SETG202
Weight
135
135
190
190
165
165
220
220
270
270
350
350
Voltage
1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V
Frequency (Hz)
50
50
50
50
50
50
50
50
50
50
50
50
Absorbed power
(kW)
1.4
0.4
1.4
0.4
1.7
0.7
3.3
0.8
3.3
0.8
4.1
1.6
Minimum power
cable section
(mm
2
)
3 x 1
3 x 0.75
3 x 1
3 x 0.75
3 x 1
3 x 0.75
3 x 1
3 x 0.75
3 x 1
3 x 0.75
3 x 2.5
3 x 1
tab. 1
Electric ovens
Gas ovens
L1 L2 L3 N
L N
Between phase
and
there must be
a difference in
potential of 230 V�
tab. 2
Fig.11