Premium pipetting comfort!

EXTREMELY LOW PIPETTING FORCEs! 

EXTREMELY EAsY TIP EJECTION!

LEGENdARY PIPETMAN RObusTNEss!

PIPETMAN G is a new mechanical, air-displacement pipette from Gilson. 
PIPETMAN G offers you the lowest pipetting force on the market thanks to a piston 
assembly system that gives you ideal  pipetting and purge forces sensations.
Enjoy a new addition to PIPETMAN line with its legendary accuracy, precision, and 
robustness… with the highest comfort!

TAKE COMfORT TO ThE NExT LEVEL

KEEP yOUR TEChNIQUE CONSISTENT 

Use PIPETMAN G like the PIPETMAN Classic! 
You can trust in your results and benefit from a great pipetting 
experience. Don’t change your habits, even the ratio between 
pipetting and purge forces is maintained!

 

Complete your equipment with:

Good Laboratory Practice (GLP) features ensure the high quality and reliability of your work.

CARROUSEL

TM

 pipette holder

(Ref. F161401)

SINGLE

TM

 pipette holder

(Ref. F161406)

TRACKMAN

TM

(Ref. F70301)

Model

Ordering reference

Volume Range

Color code

Plastic ejector

stainless steel ejector

P2G

F144054P

F144054M

0.2 µL to 2 µL

Orange

P10G

F144055P

F144055M

0.5 µL to 10 µL

Red

P20G

F144056P

F144056M

2 µL to 20 µL

Pale Yellow

P100G

F144057P

F144057M

10 µL to 100 µL

Salmon

P200G

F144058P

F144058M

20 µL to 200 µL

Yellow

P1000G

F144059P

F144059M

100 µL to 1000 µL

Blue

Model

Ordering reference

Volume Range

Color code

P5000G*

F144066

500 µL to 5000 µL

Purple

P10mL G*

F144067

1 mL to 10 mL

Light Blue

Vial of lubricant**

5440011070

For all models of PIPETMAN G

PIPETMAN G provides the legendary robustness and trustable accuracy in results of the PIPETMAN Classic. 
It perfectly fulfils your expectations in terms of pipetting comfort, even for the most intensive pipetting 
routine.

Thanks to the redesigned piston assembly (new seal, lighter springs) and the addition of high quality pis-
ton grease, you can enjoy one of the lowest* pipetting force available on the market!

GET A COMPLETE VOLUME RANGE

Get yourself a complete range of PIPETMAN G pipettes and benefit from the same 
comfort, robustness and confidence in result from 2µL to 10mL!

ChOOSE yOUR LOOK: 
CLASSIC OR MODERN DESIGN

Stainless steel or plastic ejectors are available to 
you. They both have the legendary PIPETMAN 
robustness and are equipped with a clip 
ejector for a convenient access to the 
serviceable parts.
When working with corrosive liquid we 
recommend using the plastic ejector.

TRIO

TM

 pipette holder

(Ref. F161405

EASy IDENTIfICATION

To easily distinguish your new PIPETMAN G from your PIPETMAN 
Neo or Classic pipette, a blue ring has been placed under the 
thumbwheel.

Blue ring

 = 

PIPETMAN G

Stainless st

eel ejec

tor

Pla

stic ejec

tor

Cl

ip

 eje

c

to

r

*P5000G and P10mL G models do not require tip ejectors.
**PIPETMAN G can only be lubricated with a high quality lubricant selected and approved by Gilson. The use of other types of lubricants 
will void the warranty for your pipette.

0,0

Competitor A

Volume Setting

Fo

rce (N.cm)

Newton

PIPETMAN Neo Competitor B

Model (200 or 300 µL)

Competitor C

PIPETMAN M

1,0

2,0

3,0

4,0

5,0

0

PIPETMAN G

Competitor A - Pipette 

1

Competitor B - Pipette 

1

Competitor A - Pipette 

2

Competitor C - Pipette 

1

Com

pet

itor

 A -

 Pip

ette

 4

Competitor D - Pipette 

1

Competitor A - Pipette 

3

1

3

4

5

6

2

7

8

9

10

11

Competitor E - Pipette 

1

PIP

ETM

AN

 Ne

o

Competitor B - Pipette 

2

Competitor E - Pipette 

2

Competitor 

F

Competitor E - Pipette 

3

Competitor B - Pipette 

3

Com

pet

itor

 C -

 Pip

ette

 2

Com

pet

itor

 A -

 Pip

ette

 5

Competitor D - Pipette 

2

Com

pet

itor

 C -

 Pip

ette

 3

* Tested on Gilson and other brands of 200 µL pipette or equivalent.

POS. 1 066803

POS. 2 066805

POS. 3 066807

POS. 5 066813

POS. 4 066811

Summary of Contents for Pipetman P1000G

Page 1: ...5000 12 15 30 3 5 8 40 40 40 15 15 15 P10mL G F144067 Min 1000 5000 Max 10000 30 40 60 6 10 16 60 60 60 30 30 30 Gilson s Complete Pipetting System Your protocols and experiments require more than ju...

Page 2: ...for the most intensive pipetting routine Thanks to the redesigned piston assembly new seal lighter springs and the addition of high quality pis ton grease you can enjoy one of the lowest pipetting fo...

Page 3: ...lson ISO 8655 Errore Errore Errore Errore Sistematico Casuale Sistematico Casuale P2G F144054P F144054M Min 0 2 0 5 Max 2 0 024 0 012 0 025 0 012 0 030 0 014 0 08 0 04 0 08 0 04 0 08 0 04 P10G F144055...

Page 4: ...RTANT NOTICE This pipette can be only lubricated with a high quality lubricant selected and approved by Gilson This lubricant is availableunderthereference 5440011070 Theuseofothertypeoflubricantcance...

Page 5: ...plasticorastainless steel ejector Implementation of new features to improve dramatically pipettingcomforthasnoimpactonthelegendaryrobustness accuracy and precision of Pipetman Eight single channel mod...

Page 6: ...son distributor 2 Parts Check List Just take a moment to verify that the following items are present Pipetman G User s Guide Safety bag Certi cate of conformity including bar code sticker 3 Descriptio...

Page 7: ...ing slowlyreachthe requiredsetting makingsurenottoovershootthemark whenincreasingthevolumesetting passtherequired valueby1 3ofaturnandthenslowlydecreasetoreach the volume making sure not to overshoot...

Page 8: ...ed with the adapter in place ready to use DL10 tips If D10 tips are used the adapter must be repositioned in the shorter slot as follows Pull the adapter down from the metallic rod Turn the adapter th...

Page 9: ...e levels of accuracy and precision within specifications Aspirate Press the push button to the rst stop this corresponds to the set volume of liquid Holdthepipetteverticallyandimmersethetipinthe liqui...

Page 10: ...thly When aspirating keep the tip at a constant depth below the surface of the liquid refer to the table Change the tip before as pirating a different liquid sample or reagent Change the tip if a drop...

Page 11: ...Chapter 7 Accessories Do not pipette liquids having temperatures above 70 Corbelow4 C Thepipettecanbeusedbetween 4 C and 40 C but the speci cations may vary accordingtothetemperature referto theISO86...

Page 12: ...rmity provide traceability of your pipette 9 Troubleshooting Aquickinspectionofthepipettemayhelpyoutodetect a problem YoumaydownloadfromtheGilsonwebsite www gilson com the 2minuteinspection whichshows...

Page 13: ...ting nut Pipette is Tip holder is loose Tighten connecting nut not precise Connecting nut is loose Tighten connecting nut Incorrect operator technique Operator training Damaged or corroded piston s Re...

Page 14: ...om a beaker of distilled water Maintainthepipetteintheverticalpositionandwait for 20 seconds If a water droplet appears at the end of the tip there is a leak If you see no droplet re immerse the tip b...

Page 15: ...r and its adapter With these pipettes if the tip holder is damaged the piston may also be damaged After replacing any parts you should verify the performance of your pipette following the veri cation...

Page 16: ...13 P10G P20G P100G P200G P5000G P10mlG P1000G Tip holder Tip ejector stainless steel plastic Connecting nut Color coded push button Piston assembly Blue ring...

Page 17: ...g pur posesonly Ifthepistonassemblyischanged thepipette must be adjusted and calibrated in a Gilson authorized Service Center As the models P2G and P10G contain miniaturized parts it is best not to di...

Page 18: ...del of pipette Remove the tip ejector see above Unscrew the connecting nut by turning it counter clockwise Carefully separate the lower and upper parts Remove the piston assembly O ring and seal If ne...

Page 19: ...nt free tissue soaked with distilled water Re t the tip ejector and allow the pipette to dry Internal The following components only can be immersed in a cleaning solution connecting nut tip ejector ti...

Page 20: ...You may choose to decontaminate your pipette chemi cally inaccordancewithyourownprocedures Whatever decontaminant you use check with the supplier of the decontaminant that it is compatible with stainl...

Page 21: ...is a high quality pipette that offers excel lent accuracy and precision The gures given in the Gilson Maximum Permissible Errors table page 19 were obtained using PIPETMAN Diamond Tips These gures ar...

Page 22: ...20 0 50 0 20 1 60 0 60 F144058P 100 0 80 0 25 1 60 0 60 F144058M Max 200 1 60 0 30 1 60 0 60 P1000G Min 100 3 0 6 8 3 0 F144059P 500 4 1 0 8 3 0 F144059M Max 1000 8 1 5 8 3 0 P5000G Min 500 12 3 40 1...

Page 23: ...ngs 1 tip holder ServiceKit2nd levelincludes 1 push button 1 connecting nut 2 tip ejectors for the P2G and P10G models only 1 adapter for stainless steel tip ejector 1 extension for plastic tip ejecto...

Page 24: ...tor adapter F144879 F144879 F4 Tip ejector extension F2070903 F2070903 P5000G F144066 and P10mlG F144067 Description P5000G P10mlG C D E Service Kit 1st level FA07021 FA07022 A Push button assembly FA...

Page 25: ...of the following European Directives Villiers le Bel May 3rd 2012 A El Sayed H Le Dorze General Manager Quality Manager GILSON S A S 19 avenue des Entrepreneurs BP 145 95400 Villiers le Bel France Te...

Page 26: ...shall also be void in theeventpipettesarealteredormodifiedbyanypartyotherthan Gilson or its designates Gilson s sole liability under this warranty shallbelimitedto atGilson ssoleoption repairorreplace...

Page 27: ...lson Inc World Headquarters 3000 Parmenter Street I P O Box 620027 I Middleton WI 53562 0027 USA Tel 1 800 445 7661 or 1 608 836 1551 I Fax 1 608 831 4451 Gilson S A S 19 avenue des Entrepreneurs I BP...

Page 28: ...RTANT NOTICE This pipette can be only lubricated with a high quality lubricant selected and approved by Gilson This lubricant is availableunderthereference 5440011070 Theuseofothertypeoflubricantcance...

Page 29: ...nejectorplasticorastainless steel ejector Implementation of new features to improve dramatically pipettingcomforthasnoimpactonthelegendaryrobustness accuracy and precision of Pipetman Eight single cha...

Page 30: ...son distributor 2 Parts Check List Just take a moment to verify that the following items are present Pipetman G User s Guide Safety bag Certi cate of conformity including bar code sticker 3 Descriptio...

Page 31: ...ing slowlyreachthe requiredsetting makingsurenottoovershootthemark whenincreasingthevolumesetting passtherequired valueby1 3ofaturnandthenslowlydecreasetoreach the volume making sure not to overshoot...

Page 32: ...ed with the adapter in place ready to use DL10 tips If D10 tips are used the adapter must be repositioned in the shorter slot as follows Pull the adapter down from the metallic rod Turn the adapter th...

Page 33: ...e levels of accuracy and precision within specifications Aspirate Press the push button to the rst stop this corresponds to the set volume of liquid Holdthepipetteverticallyandimmersethetipinthe liqui...

Page 34: ...thly When aspirating keep the tip at a constant depth below the surface of the liquid refer to the table Change the tip before as pirating a different liquid sample or reagent Change the tip if a drop...

Page 35: ...Chapter 7 Accessories Do not pipette liquids having temperatures above 70 Corbelow4 C Thepipettecanbeusedbetween 4 C and 40 C but the speci cations may vary accordingtothetemperature referto theISO86...

Page 36: ...rmity provide traceability of your pipette 9 Troubleshooting Aquickinspectionofthepipettemayhelpyoutodetect a problem YoumaydownloadfromtheGilsonwebsite www gilson com the 2minuteinspection whichshows...

Page 37: ...ting nut Pipette is Tip holder is loose Tighten connecting nut not precise Connecting nut is loose Tighten connecting nut Incorrect operator technique Operator training Damaged or corroded piston s Re...

Page 38: ...om a beaker of distilled water Maintainthepipetteintheverticalpositionandwait for 20 seconds If a water droplet appears at the end of the tip there is a leak If you see no droplet re immerse the tip b...

Page 39: ...r and its adapter With these pipettes if the tip holder is damaged the piston may also be damaged After replacing any parts you should verify the performance of your pipette following the veri cation...

Page 40: ...13 P10G P20G P100G P200G P5000G P10mlG P1000G Tip holder Tip ejector stainless steel plastic Connecting nut Color coded push button Piston assembly Blue ring...

Page 41: ...pur posesonly Ifthepistonassemblyischanged thepipette must be adjusted and calibrated in a Gilson authorized Service Center As the models P2G and P10G contain miniaturized parts it is best not to dis...

Page 42: ...del of pipette Remove the tip ejector see above Unscrew the connecting nut by turning it counter clockwise Carefully separate the lower and upper parts Remove the piston assembly O ring and seal If ne...

Page 43: ...free tissue soaked with distilled water Re t the tip ejector and allow the pipette to dry Internal The following components only can be immersed in a cleaning solution connecting nut tip ejector tip h...

Page 44: ...You may choose to decontaminate your pipette chemi cally inaccordancewithyourownprocedures Whatever decontaminant you use check with the supplier of the decontaminant that it is compatible with stainl...

Page 45: ...gh quality pipette that offers excel lent accuracy and precision The gures given in the Gilson Maximum Permissible Errors table page 19 were obtained using PIPETMAN Diamond Tips These gures are guaran...

Page 46: ...20 0 50 0 20 1 60 0 60 F144058P 100 0 80 0 25 1 60 0 60 F144058M Max 200 1 60 0 30 1 60 0 60 P1000G Min 100 3 0 6 8 3 0 F144059P 500 4 1 0 8 3 0 F144059M Max 1000 8 1 5 8 3 0 P5000G Min 500 12 3 40 1...

Page 47: ...ngs 1 tip holder ServiceKit2nd levelincludes 1 push button 1 connecting nut 2 tip ejectors for the P2G and P10G models only 1 adapter for stainless steel tip ejector 1 extension for plastic tip ejecto...

Page 48: ...tor adapter F144879 F144879 F4 Tip ejector extension F2070903 F2070903 P5000G F144066 and P10mlG F144067 Description P5000G P10mlG C D E Service Kit 1st level FA07021 FA07022 A Push button assembly FA...

Page 49: ...of the following European Directives Villiers le Bel March 1st 2011 A El Sayed H Ledorze General Manager Quality Manager GILSON S A S 19 avenue des Entrepreneurs BP 145 95400 Villiers le Bel France T...

Page 50: ...NOTES...

Page 51: ...ilson Inc World Headquarters 3000 Parmenter Street I P O Box 620027 I Middleton WI 53562 0027 USA Tel 1 800 445 7661 or 1 608 836 1551 I Fax 1 608 831 4451 Gilson S A S 19 avenue des Entrepreneurs I B...