Gill Instruments Ltd
_____________________________________________________________________________________________________________
__________________________________________________________________________________________________
MaxiMet
Page 68
Issue 3
Doc. No. 1957-PS-021
May 2018
PowerUp
Status Message Output:
ON or OFF
E.g.
MAXIMET GMX501-3B-0000 2669 V2.00.14
Reports MaxiMet Model details and Firmware version.
Report Message Output:
ON or OFF
E.g.
NODE,DIR,SPEED,CDIR,PRESS,RH,TEMP,DEWPOINT,SOLARRAD,
TIME,VOLT,STATUS,CHECK
Reports data string output parameters and output order.
Units Message Output:
ON or OFF
E.g.
-,DEG,MS,DEG,HPA,%,C,C,WM2,-,V,-,-
<END OF STARTUP MESSAGE>
Reports the output parameters units of measure.
MODBUS
Mode:
RTU or ASCII
Address:
1 to 247
Data Bits:
8 for Modbus RTU, 7 for Modbus ASCII
Stop Bits:
2 for No Parity, 1 for Even/Odd Parity
Parity:
NONE, ODD, or EVEN
Termination Char ASCII code:
10, (0-255)
Inter Char Timeout (mS):
1000 (500 to 10000)