Gill Instruments Ltd
_____________________________________________________________________________________________________________
__________________________________________________________________________________________________
MaxiMet
Page 53
Issue 3
Doc. No. 1957-PS-021
May 2018
GMX550/GMX600 Factory Default Data String
Items in red relate to the GPS Option Unit.
NODE, DIR, SPEED, CDIR,
CSPEED,
PRESS, RH, TEMP, DEWPOINT, TOTAL PRECIP, PRECIP INTENSITY,
GPSLOCATION,
TIME, VOLT, STATUS, CHECK
┐
Q,021,000.01,090,
000.01
,1015.3,041,+022.0,+008.5, 00000.200,000.200
,+50.763004:-
001.3.10
,2015-06-05T10:19:30.8,+05.1,0004,
└
36
Where:
┐
STX
Q
Node Letter
021
Wind Direction
000.01
Wind Speed
090
Corrected Direction
000.01
GPS Corrected Speed
1015.3
Pressure
041
Relative Humidity
+022.0
Temperature
+008.5
Dewpoint
0000.200
Precipitation Total
000.200
Precipitation Intensity
+50.763004
GPS Latitude
-001.539898
GPS Longitude
+3.10
GPS Height location
2015-06-05
Date
T10:19:30.8
Time
+05.1
Supply Voltage
0004
Status
└
ETX
36
Checksum
Notes: <STX> is the Start of String character (ASCII value 2)
<ETX> is the End of String character (ASCII value 3)
Checksum, the 2 digit Hex Checksum sum figure is calculated from the Exclusive OR of the bytes
between (and not including) the STX and ETX characters
MetSet Default Settings
REPORT : NODE DIR SPEED CDIR
CSPEED
PRESS RH TEMP DEWPOINT PRECIPT PRECIPI
GPSLOCATION
TIME VOLT STATUS CHECK
PROTOCOL : GILL
SENSOR COMPASS : ON
POWER : 0
COMMS : RS232
COMPASSDECL : +000.0
TIME : 2015-06-05T11:04:54
BAUD : 19200
SENSOR GPS : ON
AUTOTIME : ON
NODE : Q
UNITS GPS : MS
TZOFFSET : +00.00
OUTFREQ : 1HZ
SENSOR TEMP : ON
PUPMSG STATUS : ON
MSGMODE : CONT
UNITS TEMP : C
PUPMSG REPORT : ON
ASCTERM : CRLF
SENSOR DEWPOINT : ON
PUPMSG UNITS : ON
ECHO : ON
UNITS DEWPOINT : C
MODBUS : RTU
ALIGN : 0
SENSOR PRESS : ON
MODADDR : 1
SENSOR WIND : ON
UNITS PRESS : HPA
DATABITS : 8
UNITS WIND : MS
HASL : +00000.00
STOPBITS : 1
NODIR : 0.00
HASTN : +00000.00
PARITY : NONE
AVGSHORT : 60
SENSOR RH : ON
MODTERM : 10
AVGLONG : 10
UNITS RH : %
MODICT : 1000
SENSOR PRECIP : ON
UNITS PRECIP : MM