Gill Instruments Ltd
_____________________________________________________________________________________________________________
__________________________________________________________________________________________________
MaxiMet
Page 24
Issue 3
Doc. No. 1957-PS-021
May 2018
4.9.
Using SDI-12 (2 wire network, not a default setting)
MaxiMet default factory comms setting is RS232
Use MetSet to change the COMMS interface setting to SDI-12
4.10.
Using the MaxiMet GMX531 with a Supplied Kalyx Rain Gauge
or GMX550/GMX551 (user supplies a Rain Gauge)
Wiring Details
MaxiMet
9-Way Connector
SDI-12 Device
Signal Names
Pin Nos.
2 pair cable
Signal Names
SDI-12
9
SDI-12
Signal Ground
1
Signal Ground
Not connected this
end
N/A
Screen wires
Chassis Ground
ve
Supply -ve
2
3
+
-
DC power supply
MaxiMet
4-Way Connector
20m cable supplied with
GMX531
Rain Gauge
Signal Names
Pin Nos.
Signal Names
Rain Gauge
3
Contact
Rain Gauge
1
Contact
No Connection
4
Not Used
No Connection
2
Not Used
Brown
4-way connector on a 20 Metre lead
Blue
Black
White
GMX531 System
GMX551
GMX550