Figure 1. Suggested mounting bracket and Earthing (grounding) arrangements
The example shows a long mount fitted to a cable gland unit, a similar Earthing/ mounting
arrangement can be used with short mounts and connector based units.
A mounting kit (1390-10-164) is supplied with the WindObserver 65 to allow assembly of
the mount to the base of the WindObserver.
Included in the supplied mounting kit is an O Ring Seal which must be fitted inside
of the Base Mount.
Now fit the Base Mount to the WindObserver base using supplied 3 off M5x12 screws,
first fit a wavy washer to them, then a flat washer, then the seal washer before screwing to
the WindObserver Base mount.
Fit the Base Mount to the WindObserver
base using supplied 3 off M5x12 screws,
first fit a wavy washer to them, then a flat
washer, then the seal washer before
screwing to the WindObserver Base
mount