62
Fryer Operation
EOF-BIB/FFLT/24/24
5-01.11.1
Resolving Controller Errors and Alarms
●
DRAIN OPEN (Error Code OPEN) -
If the pot Drain Valve is open (even slightly) while Fryer power is
ON,
an
alarm tone sounds, 7-Segment Display shows
OPEn,
and the
OLED Display
reads
“ERROR ALARM - DRAIN IS
OPEN”.
If the Basket Lift is down, it will be raised. Heating Elements are disabled as long as the condition exists.
Press the
[ALARM]
key to silence alarm tone. Completely close the Drain Valve to clear the error. When error is
cleared, alarm tone sounds again and the OLED Display reads
“CHECK OIL LEVEL, ENSURE VAT IS FULL, IF FULL
THEN PRESS [START]”.
This is a post-error alarm to alert user to confirm that cooking oil in the pot is still at the
FULL
level. Add oil if needed, then press the
[START]
key to return to
PREHEAT
mode.
●
MAX. ELEMENT TEMP (Error Code 19) -
Heating Element has exceeded the maximum temperature allowed by
the Controller. The alarm tone sounds, 7-Segment Display shows
Er19,
and the OLED Display shows
“ERROR
ALARM - MAX ELEMENT TEMPERATURE”.
Heating Element is automatically turned
OFF.
It must cool to an
acceptable temperature to clear the error. Typical cause of this error is low oil level, which has exposed the
heating element. It is possible for a false alarm to occur when preheating cold oil at the initial startup of a new
day. Vigorously stirring oil during preheat will usually prevent, or clear, a false alarm of this type.
●
MAX ELEMENT TEMP Post-error Warning (Error Code 07)
- After
Error 19
is cleared, a warning alarm occurs.
The 7-Segment Display shows
Er07,
and the OLED Display reads
“MAX ELEMENT TEMP - PRESS [START]”.
This
alarm alerts user that a maximum element temperature error occurred and is now cleared. Press
[START]
key to
enter
PREHEAT
mode. Heating Element will not turn
ON
until
[START]
is pressed.
●
BAFFLE FILTER MISSING (Error Code 21) - Not Applicable
●
CHARCOAL FILTER MISSING (Error Code 22) - Not Applicable
●
CLOGGED FILTER (Error Code 23) - Not Applicable
●
E.A.C. DIRTY (Error Code 24) - Not Applicable
NOTE: If an error condition cannot be resolved, please contact a factory-authorized service agent, or call
800.554.4537 for Giles Technical Support.
Summary of Contents for EOF-BIB/FFLT/24/24
Page 4: ......
Page 8: ...vi Table Of Contents EOF BBIB FFLT 24 24 Notes ...
Page 24: ...12 Overview EOF BIB FFLT 24 24 3 01 EOF BIB Vat Control Panel 5 1 4 6 2 3 ...
Page 26: ...14 Overview EOF BIB FFLT 24 24 3 02 EOF BIB Lower Cabinet Area 2 1 Hidden ...
Page 28: ...16 Overview EOF BIB FFLT 24 24 3 03 FFLT Dump Station 2 1 ...
Page 30: ...18 Overview EOF BIB FFLT 24 24 3 04 FFLT Control Panel 1 ...
Page 32: ...20 Overview EOF BIB FFLT 24 24 3 05 FFLT Lower Cabinet Area 1 2 3 4 5 6 ...
Page 34: ...22 Overview EOF BIB FFLT 24 24 3 06 EOF 24 Basket Lifts Baskets 4 2 1 3 Hidden ...
Page 40: ...28 Overview EOF BIB FFLT 24 24 3 09 EOF 24 Lower Cabinet Area 1 2 ...
Page 42: ...30 Overview EOF BIB FFLT 24 24 3 10 Filter Pan Assembly 5 6 3 2 1 4 3 ...
Page 104: ...92 Parts List 1 8 02 EOF BIB Control Panel Front Header 5 6 7 8 9 EOF BIB FFLT 24 24 4 3 2 ...
Page 112: ...100 Parts List EOF BIB FFLT 24 24 1 3 2 4 5 6 8 06 EOF BIB Rear Cabinet ...
Page 116: ...104 Parts List 8 08 FFLT Lower Front Cabinet 1 3 4 5 7 8 2 6 EOF BIB FFLT 24 24 Not Shown ...
Page 118: ...106 Parts List 2 8 09 FFLT Cabinet Rear 1 Not Shown 4 3 EOF BIB FFLT 24 24 ...
Page 122: ...110 Parts List Notes EOF BIB FFLT 24 24 ...
Page 123: ......