Configuration Dipswitches:
There are two opto-isolated inputs on each MiniRepeater which can be
used for starting, stopping, and resetting them. All configuration for the DR-
50Õs is done on an eight position Configuration Dipswitch (nine positions on
the AB-50). These are used as follows:
S
WITCH
#1: R
ESET FROM
ÔAÕ:
When this switch is turned on, the repeater will reset to the begin-
ning of the first spiel every time the ÔAÕ input is activated. This is an
edge triggered input activated on the closing edge of the input.
S
WITCH
#2: R
ESET FROM
ÔBÕ:
When this switch is turned on, the repeater will reset to the begin-
ning of the first spiel every time the ÔBÕ input is activated. This is edge
triggered input activated on the closing edge of the input. Closing
Switch #8 removes the one-shot circuit from this input for applica-
tions where the reset signal must be held.
S
WITCH
#3: S
TOP FROM
ÔAÕ:
When this switch is turned on, the repeater will stop when the A
input is released. This allows you to set up a card to start running
when the A input is activated and stop as soon as this input is re-
leased. This can be used in conjunction with Switch #1 if you would
like the repeater to always restart at the beginning of the first spiel.
S
WITCH
#4: S
TOP FROM
ÔBÕ:
When this switch is turned on, the repeater will stop when the B
input is activated. When used in conjunction with Switch #8 it will ef-
fectively lock out any starts from the card as long as the B input is
held active.
S
WITCH
#5: E
NABLE
S
TOP
:
When this switch is turned on, the repeater will pay attention to
the ÔstopÕ commands encoded into the Eprom. When off it will re-
peatedly play whatever is recorded on the Eprom until it is explicitly
told to stop. You can use this switch to make a repeater start running
from a pulse on the A input until you tell it to stop with a pulse on the
B input.
To loop a sound on a AB/DR-50 with a delay between each itera-
tion of the loop you will need to record tow spiels on the repeater.
The first is the actual spiel you want to play. The second is a ÔsilentÕ
spiel that is the length of the delay between each loop iteration. This
ÔsilentÕ threshold is usually recorded at a 2 KHz sample rate with a 0
KHz filter rate. With this switch ON, the repeater will play both spiels
as one.
S
WITCH
#6: M
UTE
E
NABLE
:
When this switch is turned on, the repeater will activate the mute
input on the filter chip whenever the repeater is stopped. This re-
duces the quiescent noise level from the card and so is almost al-
ways left ÔonÕ.
S
WITCH
#7: ÔAÕ I
NPUT
C
ONTINUOUS
:
When this switch is turned on, the A input is held continuously acti-
vated. Turning this switch on is the easiest way to make a card start
looping as soon as power is applied. With this switch on the only way
to stop the repeater is to turn on switches #2 and #8, and use the B
input to stop (actually reset) the repeater.
S
WITCH
#8: ÔBÕ I
NPUT
C
ONTINUOUS
:
G
ILDERFLUKE
& C
O
.
¥
205 S. F
LOWER
¥
B
URBANK
, C
A
91502-2102
¥
818/840-9484
¥
800/776-5972
¥
F
AX
818/840-9485
55 of 72