background image

MDE-2597L Gilbarco® Security Module (GSM) PA0258XXXXXXX Installation and Service Instructions · January 2010

Page 1

Introduction

Purpose

This manual provides the product overview, installation instructions, troubleshooting, and 
other important information for the Gilbarco

®

 Security Module (GSM). This revision contains 

the following:

• Information previously published in the customer-specific addenda.
• Instructions for 

Installing PA025801XXXXX GSM in SMART CRIND™”

.

Table of Contents

Topic

Page

Introduction

1

Important Safety Information

6

Installation

8

System Operation

18

Testing and Troubleshooting

21

Important Shelf Life Information

Plug the GSM into a wall outlet immediately upon receipt.

 An internal battery retains 

factory programming. This internal battery has a shelf life of approximately six months from 
the factory start-up date. The label affixed to the GSM housing records the factory start-up 
date. The battery is not rechargeable.

If the internal battery discharges fully, the GSM will no longer be usable

. For 

this reason, once you install the GSM, 

do not

 shut off the AC power to the GSM. 

Reserve the internal battery power for power failure backup.

CAUTION

Product Overview

The GSM is a security device that encrypts (encodes) the data entered at the Card Reader In 
Dispenser (CRIND

®

) device or PIN pad during a debit sale, for transmission from the site 

controller to the debit card network host. The site controller may be a C-2 G-SITE

®

 Point Of 

Sale (POS) system, PC-based G-SITE POS system, Passport

®

 POS system, or a third-party 

controller.

The GSM is powered by a separate power supply, and is cabled to the site controller through 
an RS-232C Port labeled “To Controller”. A status Light Emitting Diode (LED) or light 
displays the GSM’s current state.

MDE-2597L

Gilbarco

®

 Security Module (GSM) PA0258XXXXXXX 

Installation and Service Instructions

January 2010

Summary of Contents for PA025800 Series

Page 1: ...up date The label affixed to the GSM housing records the factory start up date The battery is not rechargeable If the internal battery discharges fully the GSM will no longer be usable For this reaso...

Page 2: ...0 20B Black 1 RJ 45 to 9 pin Male Cable Adapter M09747B010 1 Gender Mender 25 pin Controller to Modular Cable Q13180 22B Black 1 GSM PA0258XXXXXXX 1 GSM Power Supply 5 V OUT or 90 260 VAC IN Q13698 03...

Page 3: ...affixed to the GSM housing Upon receipt the GSM must be maintained under power to retain programming If the internal battery is allowed to discharge completely the GSM will no longer be usable Note GS...

Page 4: ...p max Related Documents Document Number Document GOLD Library MDE 2530 Pump and Dispenser Installation Manual The Advantage and Legacy Models MDE 3110 PC based G SITE System Installation Manual G SITE...

Page 5: ...bbreviations and Acronyms Term Description ANSI American National Standards Institute CRIND Card Reader IN Dispenser GSM Gilbarco Security Module ISO International Organization for Standardization LED...

Page 6: ...ng work Follow the Regulations Applicable information is available in National Fire Protection Association NFPA 30A Code for Motor Fuel Dispensing Facilities and Repair Garages NFPA 70 National Electr...

Page 7: ...ace any equipment in the mouth In an Emergency Inform Emergency Personnel Compile the following information and inform emergency personnel Location of accident for example address front back of buildi...

Page 8: ...Locate the GSM in a position away from direct sunlight If necessary provide a suitable sun screen Installing Cables Install all cables so that they are protected from damage or accidental disconnectio...

Page 9: ...ple Shell Oil Company GSM with PA02580000SHL Figure 1 Installing the GSM Power Module Q12538 01 or Q13698 03 Part of PA025800XXXXX GSM Model No PA025800XXXXX Isolated Ground Outlet POS System CPU Cont...

Page 10: ...em T17361 15 2 or later T17764 M03651A001 A002 16 0 or later M04108A001 02 x x Third party T17361 50 2 4 T17764 M03651A001 A002 51 1 6 60 x x or 62 x x M04108A001 02 x x 3 Position the unit within 10...

Page 11: ...POS System Q13180 04B Q13180 20B M09747B010 Q13180 63B 5 5 Power Module Q13698 03 Part of PA02580000XXX Passport Edgeport USB to RS 232 Converter Passport Enhanced Dispenser Hub PA04030000 2 Connect...

Page 12: ...third party controller programming by checking for the following Correct addresses Poll Cluster Select Correct number of Terminal IDs Correct Terminal IDs Correct Terminal address Correct device type...

Page 13: ...o Testing and Troubleshooting on page 21 Connecting the GSM to Passport V3 6 to V8 0 To connect the GSM to the Passport system proceed as follows 1 Connect a 9 pin RPCI Gender Mender Q13180 04B to the...

Page 14: ...lays OUT OF SERVICE or ONE MOMENT PLEASE open the G SITE POS system shift If the CRIND device displays PLEASE PAY INSIDE and beeps it implies that the third party controller is not polling the CRIND d...

Page 15: ...r applications that do not have a NEMA 5 15 style outlet the customer must supply a connector and attach it to the end of a Q11736 01 Cable 9 Turn on power to the Controller 10 Verify the Passport POS...

Page 16: ...lows 1 Install the GSM sideways into the slot next to the UPS and main power supply from Side 2 Figure 4 Installing the GSM Sideways Bolts that secure the GSM to the frame 2 Secure the GSM onto the fr...

Page 17: ...n ISO PIN key management security guidelines the security regulations mandated by the networks require that all cryptographic devices removed from service have their encryption keys erased destroyed A...

Page 18: ...ls such as lithium and lead that cannot be disposed of using regular procedures It must be disposed of with a processor that can accommodate hazardous materials For your convenience you may return the...

Page 19: ...s LED will blink ON and OFF continuously approximately once per second as shown in Figure 7 This GSM is ready for debit For DUKPT LED Pattern Indication Continuous ON OFF Flash see Figure 7 GSM good R...

Page 20: ...ownload network working key from network host LED constantly on or LED constantly off Replace GSM Fatal diagnostic code Very Slow Blinking Powerfail GSM by disconnecting the AC side of the power suppl...

Page 21: ...2 Check GSM For Diagnostic Code Request New Start up From Network Attempt Debit At CRIND Device Debit Unsuccessful DONE Debit Successful Go To Step 3 STEP 3 Cycle Power at GSM CRIND Device Console At...

Page 22: ...y 2010 CRIND Gilbarco G SITE Legacy Passport and The Advantage are registered trademarks of Gilbarco Inc Hubbell is a registered trademark of Hubbell Inc Mannatec is a registered trademark of Mannatec...