MDE-5386D Hybrid Card Reader S (HCRS) Kit (M13940KXXX) Installation Instructions (Canada) · June 2020
Page 19
Installing HCRS Kit in Encore S E-CIM Units
6
Check the gasket from outside of the door to ensure no gasket material is visible around the
card reader bezel.
7
Remove the protective foam block and with power off, connect the 7-pin Power/Data Cable
(M07702A023) to the 7-pin power/data connector on the HCRS.
Notes: 1) Orient the connector as shown in
.
2) The HCRS is equipped with a chassis ground connection that must be connected to
the chassis. The HCRS will be shipped with the ground connected to the card reader.
The other end must be adhered to the chassis.
Figure 12: Connecting Ground Cable to Chassis
Ground Cable
U-channel
8
Connect the card reader cable to the card reader port on the SPOT, and P206 on the SIP
(see
).
9
Connect the J2125 to P2125 on the door node/display board. Intercept the existing connector
that is already connected to P2125, if already present.
10
Ensure that the power/data cables are secured to the unit with sufficient slack to prevent cable
pulls and pinching when opening/closing the door.
11
Proceed to
on
.