Page 12 MDE-5386D Hybrid Card Reader S (HCRS) Kit (M13940KXXX) Installation Instructions (Canada) · June 2020
Installing HCRS Kit in Encore 300/500 Units
5
Align the HCRS and card reader bracket. Securely tighten the four mounting screws in stages
in a diagonal pattern with a torque wrench driver to ensure correct seating of the card reader.
Do not overtighten the screws. Overtightening of the screws can strip or break the card reader
bosses.
The following are the torque settings for the different door types:
• Non-threaded insert doors: 18 +/- 2 inch-lbs
• Threaded insert doors: 12 inch-lbs
6
Check the gasket from outside of the door to ensure no gasket material is visible around the
card reader bezel.
7
Remove the protective foam block and with power off, connect the 7-pin Power/Data Cable
(M07702A023) to the 7-pin power/data connector on the HCRS.
Notes: 1) Orient the connector as shown in
2) The HCRS is equipped with a chassis ground connection that must be connected to
the chassis. The HCRS will be shipped with the ground connected to the card reader.
The other end must be adhered to the chassis.
3) If a Global Contactless Module (GCM) is installed, ensure there are no unit ground
wires running across the back of the GCM. This will help prevent any noise
interference.
8
Connect the card reader cable to the card reader port on the SPOT display and P206 on the SIP
board (see
on
).
The connection between the money/volume display is NOT MADE for Encore 300. If this is
an Encore 300 unit, skip to step
.
9
For Encore 500 with Door Node 3 (M04326), Door Node 4 (M05835), or Door Node 5
(M12605), an Extension Cable (M07974A005) is required for the Cable (M07702A023) to
reach the door node.
a
Locate the Cable (M07702A023) on the door.
b
Connect the P2125A on Cable (M07974A005) to the J2125 on Cable (M07702A023).
c
Connect the J2125 on Cable (M07974A005) to the P2125 on the door node.
Note: P2125A on the Cable (M07702A023) remains available for other connections.
Figure 5: Connecting Cables for Encore 500
JHCR
P212
5A
J2125
J2125
J206
P2125
A
Ferrite
Connects to
SIP
M07974A005
Cable
Connects to
P2125 on
Door Node
Card Reader Cable
(M07702A023)
Card
Reader
Available
Connects
to HCRS
Connects to
EMV CRIND