48
Te
mplat
e
G
o
, V
e
rs
ion 1
, 01.
07
.2
014
/ M
odu
leV
e
rs
ion 1
.0
Operating the base on the PABX
Gigaset E560A / LUG GBR en / A31008-M2708-L101-1-7619 / settings_BS.fm / 7/14/16
Operating the base on the PABX
The following settings are only necessary if your PABX requires them; see the PABX user guide.
Changing the dialling mode
¤
Menu
Enter digit for the dialling mode
:
= tone dialling (DTMF);
= pulse dialling (PD)
OK
Switching temporarily to tone dialling (DTMF)
If your PABX still operates with pulse dialling (PD), but you need tone dialling for a connection
(e.g., to listen to the network mailbox), you must switch to tone dialling for the call.
Prerequisite:
You are conducting a call or have already dialled an external number.
¤
Press the star key
.
Tone dialling is now activated
for this call only
.
Setting recall
¤
Menu
Enter digits for recall:
= 80 ms; = 100 ms; = 120 ms; = 400 ms; = 250 ms; = 300 ms;
= 600 ms; = 800 ms
OK
Changing the pause after line seizure
You can set the length of the pause inserted between pressing the talk key
and sending the
phone number.
¤
Menu
Enter digit for the current pause length:
= 1 second;
= 3 seconds;
= 7 seconds
OK
Changing the pause after recall key
¤
Menu
Enter digit for the current pause length:
= 800 ms;
= 1600 ms;
= 3200 ms
OK
Operating the telephone on a router
Operation with a router
When operating on the analogue connection of a router, potentially occurring
echoes
can be
reduced by switching on
XES mode 1
(
XES = "e
X
tended
E
cho
S
uppression").
If there are no problems with echoes, the normal mode (factory settings) should be activated.
¤
¤
OK
(for normal mode)
¤
OK
(for XES mode 1)