System Hardware Installation
3-4-4 Intel Optane DCPMM DIMM Population Rule
Thermal conditions for DCPMM DIMM support:
•
The ambient temperature must be at or below 35°C
•
The Cascade Lake CPU used must have a maximum TDP of 165W
•
A maximum of 12 pcs 256G DCPMM may be installed
• RDIMM / DCPMM must be installed into CPU0 memory first
•
You must install one RDIMM into any slot #0 of CPU0 before installing the DCPMM.
(e.g. A0/B0/C0/D0/E0/F0/G0/H0/I0/J0/K0/L0)
•
The DCPMM must be installed into the DIMM slot #1 next to the corresponding RDIMM
in slot #0 (e.g. if RDIMM is installed into DIMM slot A0, the DCPMM must be installed into
DIMM slot A1)
DIMM_P0_D0/RDIMM Slot
DIMM_P0_D1/Int
el Optane DCPMM Slot
DIMM_P0_E1/In
te
l Optane DCPMM Slot
DIMM_P0_F0/RDIMM Slot
DIMM_P0_E0/RDIMM Slot
DIMM_P0_F1/Int
el Optane DCPMM Slot
DIMM_P0_C1/Int
el Optane DCPMM Slot
DIMM_P0_C0/RDIMM Slot
DIMM_P0_B0/RDIMM Slot
DIMM_P0_A1/Int
el Optane DCPMM Slot
DIMM_P0_B1/Int
el Optane DCPMM Slot
DIMM_P0_A0/RDIMM Slot
DIMM_P1_J0/RDIMM Slot
DIMM_P1_J1/Int
el Optane DCPMM Slot
DIMM_P1_K1/Int
el Optane DCPMM Slot
DIMM_P1_L0/RDIMM Slot
DIMM_P1_K0/RDIMM Slot DIMM_P1_L1/In
te
l Optane DCPMM Slot
DIMM_P1_I1/Int
el Optane DCPMM Slot
DIMM_P1_I0/RDIMM Slot
DIMM_P1_H0/RDIMM Slot DIMM_P1_H1/Int
el Optane DCPMM Slot
DIMM_P1_G0/RDIMM Slot
CPU0
(Primary)
CPU1
(Secondary)
DIMM_P1_G1/Int
el Optane DCPMM Slot
Summary of Contents for G191-H44
Page 10: ... 10 This page intentionally left blank ...
Page 16: ... 16 Hardware Installation This page intentionally left blank ...
Page 22: ... 22 System Appearance This page intentionally left blank ...
Page 27: ... 27 System Hardware Installation 4 3 1 2 6 5 ...
Page 36: ...System Hardware Installation 36 This page intentionally left blank ...
Page 40: ... 40 Motherboard Components This page intentionally left blank ...
Page 49: ... 49 BIOS Setup 5 2 3 Intel R I350 Gigabit Network Connection ...
Page 51: ... 51 BIOS Setup 5 2 4 VLAN Configuration ...
Page 52: ...BIOS Setup 52 ...
Page 54: ...BIOS Setup 54 5 2 5 Intel R Omni Path HFI 100 Series ...
Page 56: ...BIOS Setup 56 5 2 6 Intel R Ethernet Controller X550 ...
Page 64: ...BIOS Setup 64 5 2 11 PCI Subsystem Settings ...